230 V
Gas
1
fi g. 56
Open the boiler
LT.AL.W7H.000.058
2x
fi g. 57
Maintenance the electrode
LT.AL.W7H.000.059
2
3.2

Maintenance

To conduct maintenance:
Ensure that a service gasket set and new ignition/ionisation
electrode is available before carrying out this procedure.
• Isolate power supply at the fused spur before carrying out
any work on the boiler.
1. Open the boiler
• Isolate the 230 V supply at the switched spur and remove
the fuse
• Isolate the gas supply at the boiler gas valve
• Remove the front panel (release the two screws at the bot-
tom of the front panel, pull the bottom of
the panel forward and lift off the two pins on the top of the
main casing).
2. Maintenance of the ignition/ionisation electrode
• Disconnect the earth wire from the electrode mounting
plate.
• Release the two screws on the electrode and remove the
assembly.
• Inspect, clean re-gap or replace the electrode, see par 0.