Junction Box Installation; Wall Switch Installation For Fan (Optional) - Outdoor Lifestyles TWILIGHT-II-MOD Owner's Manual

Gas fireplace
Hide thumbs Also See for TWILIGHT-II-MOD:
Table of Contents

Advertisement

E. Junction Box Installation
If the box is being wired from the OUTSIDE of the appliance:
• Install the Romex™ connector (not included with
appliance) in the side wrap.
• Loosen two screws on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections.
If the box is being wired from the INSIDE of the appliance:
• Remove the screw attaching the junction box to the
outer shell, rotate the junction box inward to disengage
it from the outer shell (see Figure 9.4).
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Loosen the two screws on the Romex connector, feed
the necessary length of wire through the connector and
tighten the screws.
• Make all necessary wire connections to the receptacle
and assemble the receptacle and cover to the junction
box.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall mounted switch for use
with a fan (See Figure 9.5):
• The power supply for the appliance must be brought into
a switch box.
• The power can then be supplied from the switch box to the
appliance using a minimum of 14-3 with ground wire.
• At the switch box connect the black (hot) wire and red
(switch leg) wire to the wall switch as shown.
• At the appliance connect the black (hot), white (neutral)
and green (ground) wires to the junction box as shown.
• Add a 1/4 in. insulated female connector to the red (switch
leg) wire, route it through the knockout in the face of the
junction box, and connect to the top fan switch connector
(1/4 in. male) as shown.
28
Outdoor Lifestyles by Hearth & Home Technologies, Inc. • TWILIGHT-II-MOD • 2290-900 Rev. C • 7/12
HEAT SHIELD
BLK
WHT
BLK
WHT
Figure 9.4 Junction Box Detail
Minimum 14-3 AWG
with Ground
Junction Box
Red
Figure 9.5 Junction Box Wired to Wall Switch or BC10
14/2WG
COPPER GROUND
ATTACHED TO GRN SCREW
WITH GRN WIRE
GREEN WIRE
INSIDE BOX
NOTE: Do NOT wire
110 VAC to wall switch.
Switch
Red
Black
Black
White
White
Green
Green
Power
Switch Box
Supply
Wires
Knockout