10. Are there Cycle Time adjustments on the Control Board for different types of fuel?
Answer: There are 4 individual programs on the control board, each
with a different Cycle time.
The Control board has been factory set at the 8.5-second Cycle Time.
When reprogramming the control board, you will see LED light flash,
as shown in the figure to the right. The LED lights flash in the
following manner:
Program 1 - 8.5 second cycle time. The LED's flash once. This
program is for use with Pellets, Corn, Wheat or Rye. (When using this
program with Wheat or Rye, the ON-Times may need to be decreased.
See point 8 on page 55).
Program 2 - 7.5 second cycle time. The LED's flash twice. This
program is for use with Pellets & Corn.
Program 3 - 6.5 second cycle time. The LED's flash three times.
This program is for use with Pellets & Corn (When using this program
with Corn, the ON-Times may need to be decreased. See point 8 on
page 55).
Program 4 - 5.5 second cycle time. The LED's flash four times.
This program is for use with Pellets only.
11. How do I change to a different Program on the control board?
First the furnace must be turned off and cooled down.
Step 1 - The Thermostat switch must be in the Manual position.
Step 2 – Press and hold the Trim High and Low Buttons.
Step 3 – Press the Auger Feed Button. Release all 3 buttons at the
same time.
Step 4 – Observe the LED light flashing as described in point 10
above.
Changing the Cycle Time will change the BTU Input of the furnace.
The longer the Cycle time the lower the BTU rating.