Periodic Maintenance

CAUTION: Periodic maintenance should only be done while the Furnace is shut off and
cold.
1.
Ashpan. Empty the ash pan when it appears full (approximately twice a week). The
frequency of cleaning the ash pan will depend on the quality and amount of
Corn/Pellets being used. Carefully check to make sure the ash pan door is tightly
closed after each opening.
2. Revolution Burnpot. Clean burn grate holes whenever needed. Clean the burnpot
while it is in the furnace. Remove the pot Side Shields (See Figure 12 on Page 23)
and use a stiff bristle brush to remove any ash build up in each section.
Figure 22
By tripping the switch lever, shown
in detail in figure 19, the burn pot
will cycle to another section.
Repeat this until all 4 sections of
the drum have been cleaned. Check
each section with a small mirror to
see they are clean.
If the holes in the pot remain
plugged, remove the Burnpot, (as
shown in Figure 12 on Page 23)
and use a small metal object (Nail,
Drill Bit, etc) to clean out plugged
holes.