1. Exhaust System. Periodic cleaning of the exhaust system is required. Under certain
conditions chimneys may plug up rapidly. Dirty/High moisture content Corn or
Pellets with high ash content and installations with elbows and horizontal runs require
more frequent chimney cleanings. See Page 22 "Preventing Chimney Fires". The
products of combustion will also contain small particles of fly ash. The fly ash will
collect in the exhaust vent and restrict the flow of the flue gases. Judge the frequency
of cleaning by checking the amount of ash that accumulates in the elbows or tee's of
the exhaust system. Ask the dealer for suggested frequency of cleaning, equipment
needed and procedures for cleaning. Check the Exhaust system at least once every
two months during the heating season.
2. Gaskets. Periodically inspect the condition of the rope gasket around the door,
window and ash door. Replace as needed.
3. Air Filter. Check the Return Air Filters at least once a month and replace when
needed. The size of the filter is 1" X 16" X 25".
To remove the baffle, lift the back of the
baffle up to clear the inner back of the Furnace
and slide towards the front of the Furnace. The
baffle will slide out of the keyhole slots and
drop down. When putting the baffle back in
the Furnace, make sure the Tabs are in the
Keyhole slots and the back of the baffle is
lifted up over the inner back to keep the
Baffle locked in place.
SCF-Revolution Manual
43
Baffle Removal
Figure 24