Additional Canadian Installation requirements.

1.
The fans of this Furnace may cause a negative pressure area in the room where this
Furnace is installed. If the Furnace is not connected to a Return Air duct system in the
house, provision should be made to provide make-up air to the unit. It is
recommended to provide opening equal to 120 Square inches for Return Air to the
Furnace room.
2.
Outside Combustion Air may be needed if:
a. The unit does not vent steadily, smell, experiences smoke rollout, burns poorly, or
back drafts whether or not there is combustion present.
b. Any of the symptoms listed above are alleviated by opening a window slightly on
a calm day.
c. The house is sealed with a well-sealed vapor barrier and tight fitting windows and
doors and/or has any powered devices, which exhaust house air.
d. There is excessive condensation on the windows during the winter.
e. A ventilation system is installed in the house
3.
Adhere to all Clearances and Restrictions specified in the Installation Instructions of
this furnace.

Additional Canadian Operation Requirements.

1.
Store Corn/Pellets in sealed containers in a dry environment to prevent the fuel from
absorbing moisture and becoming damaged.
2.
Creosote formation and Cleaning.
a. Establish a routine for the storage of fuel, care of the Furnace and Firing
Techniques.
b. Check Daily for Creosote build-up until experience shows how often cleaning is
necessary.
c. Be aware that the hotter the fire, the less creosote is deposited, and that weekly
cleaning may be necessary in mild weather, even though monthly cleaning may
be enough in the coldest months. Run the furnace on the hottest setting once a day
for 30 – 45 minutes to prevent excessive build-up in the furnace.
d. Have a clearly understood plan to handle a chimney fire. Contact the local fire
department for information if needed.
e. Keep the doors closed and all seals in good condition while operating the furnace.
f. INSPECT THE FLUE PIPES, JOINTS AND SEALS REGULARLY TO
ENSURE THAT SMOKE AND FLUE GASES ARE NOT DRAWN INTO,
AND CIRCULATED BY THE AIR-CIRCULATION SYSTEM.
g. CLEANING OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY AND
DRAFT INDUCER IS ESPECIALLY IMPORTANT AT THE END OF THE
HEATING SEASON TO MINIMIZE CORROSION DURING THE SUMMER
MONTHS CAUSED BY ACCUMULATED ASH.
h. Do Not Use Chemicals or Fluids to Start The Fire.
SCF-Revolution Manual
51