VENTING: APPROVED MATERIALS

The Furnace requires a venting system approved for pellets by a certified testing lab. Approved
pellet Furnace venting materials are: 1) PL vent, a double wall vent with a stainless steel liner;
and 2) Single wall rigid or flexible stainless steel pipe. PL Vent and Single wall vent is available
through manufacturers such as: Energy Vent LTD, James A. Ryder, Simpson DuraVent and
Selkirk Metalbestos and is carried by many local pellet Furnace dealers. In this manual approved
venting will be referred to a "PL vent" or "Single wall vent". All single wall vent adaptors must
be stainless steel.
NOTE: TYPE "B" GAS VENT MUST NOT BE USED IN THE INSTALLATION OF THIS
FURNACE
Examples of venting system components follow:
High temperature ceramic roping reduces potential fly ash escaping through joints.
Stainless steel inner liners resist corrosive flue gas damage to the system.
Flex pipe should be stainless steel, 4 ply construction with a total thickness of approx. .07 inches.