4. Permanently bolt the Furnace to the floor.
5. Electrically ground the Furnace and pedestal to the metal chassis of the home. Use a number eight,
(8) gauge or larger copper wire.
6. Maintain an effective vapor barrier at location where PL vent exits the structure.
7. Check any other local building codes or other codes that may apply.
8. Do no use components other than those specified for use with this unit.
9. Floor protection requirement must be followed precisely.
10. PL Vent must be used for exhaust venting. (Single wall vent is not allowed). Follow PL Vent
manufacturer's installation directions and observe all listed clearances to combustibles.
DO NOT CONNECT THE SCF-REVOLUTION FURNACE TO A DOWN FLOW FURNACE
SYSTEM.
NOTE: Installers must determine a neutral location of where to mount the Thermostat in order
for accurate room temperature measurements.

Thermostat Connections

Figure 12
SCF-Revolution Manual
21
Wiring Connections
To hook up a thermostat,
connect the wires from the
thermostat to the external
Wire Terminal on the left
side of the Furnace. The
external Terminal has been
pre-wired to the thermostat
connections on the back of
the control board.
For Information on how the
Thermostat operates, please
read the section covering
thermostat operations.