SECTIoN 6

6.5 reference Voltage Checks

a. Control Board assembly (PCB1)
1.
Voltage Test Points - Tests are made with power on - no arc.
TP-15
-
Ground
TP-12
-
+15 vdc
TP-13
-
+5 vdc
TP-14
-
-15 vdc
B. Interface Board (PCB2)
1.
Voltage Test Points
TP-1
-
+24 vdc
TP-2
-
+24 vdc com
36 vdc
15 vdc
0
2.
54 µsec
For 208/230 VAC input, the IGBT off time is 3µsec.
For 400/460 VAC input, the IGBT off time is 3µsec.
figure 6.1 IgBT gating Signal