Performing Install Routine; Detent Pin Adjustment - Wayne-Dalton Optimal Installation, User Operation & Maintenance Manual

Table of Contents

Advertisement

10
NOTE: The opener can be activated by up to six remote control devices (including Wall Station and keyless entry controls). If a
Tools Needed:
seventh control is programmed, one of programmed controls will be over ridden and will no longer activate the opener.
None
To clear programming of all remote control devices, press and hold opener program button (1w) for approximately ten seconds.
When the opener beeps three times, all remote controls are erased.
NOTE: Manually disconnect the opener using the emergency disconnect handle prior to erasing remote controls.
11
Tools Needed:
WARNING
None
If no obstructions interfere with the door opening completely, proceed with INSTALL ROUTINE WITH STANDARD UPPER
LIMIT. However, if an object such as a ceiling beam obstructs the door from opening completely, set a custom upper limit
setting during the install routine, INSTALL ROUTINE WITH CUSTOM UPPER LIMIT.
IMPORTANT: Door must be in its fully closed position to initiate install routine.
INSTALL ROUTINE WITH STANDARD UPPER LIMIT USING WALL STATION WHEN SUPPLIED:
Press and hold the profile button (2c) for five (5) seconds. The opener will beep twice, indicating the activation of the install
routine, release the profile button (2c). The door will now move to the fully open position and stop. Then, the door will close
completely. Next, the door will go through one more up/down cycle. Once this is complete, the door limits are set and the install
routine is complete.
INSTALL ROUTINE WITH STANDARD UPPER LIMIT USING TRANSMITTER WHEN WALL STATION IS NOT SUPPLIED:
Press and hold the two small buttons of the transmitter (2n and 2m) simultaneously for five (5) seconds. The opener will beep
twice, indicating the activation of the install routine, release the transmitter's buttons (2n and 2m). The door will now move to
the fully open position and stop. Then, the door will close completely. Next, the door will go through one more up/down cycle.
Once this is complete, the door limits are set and the install routine is complete.
INSTALL ROUTINE WITH CUSTOM UPPER LIMIT:
Press and hold the profile button (2c) of the wall station (or the two small buttons of the transmitter (2n and 2m)
simultaneously) for five (5) seconds. The opener will beep twice, indicating the activation of the install routine. When the door
moves to the desired height, at least 1,2 m off the ground, press the up/down button (2d) on the wall station (or the
programmed button on the transmitter). The door will stop and then close completely. Next, the door will go through one more
up/down cycle. Once this is complete, the door limits are set and the install routine is complete. Alternate: after an install routine
has been completed, the door can be disconnected and manually moved to the desired upper limit. Reconnect door and initiate
a new install routine from the new upper position.
12
Tools Needed:
IMPORTANT: FOR SYSTEM SECURITY: The motor is designed to pivot down after the door closes completely. If the motor
does not pivot or pivots too soon, the detent may need to be adjusted in order for the door lock feature to work properly.
Screw Driver (Flat
Head)
The amount of pressure the opener uses to pivot motor and lock arm downward is preset at factory via detent pin adjusting
screw (2g). Since all door counterbalances are different, detent position is preset for an optimal balanced door. If door is out of
balance slightly, a detent pin adjustment will need to be made with a screwdriver in order for proper pivoting of the motor.
Transmitter Security Code Change and Programming - Continued
(see Diagram 10 on page 9 of Drawings of Installation, Use and Maintenance manual)
(see Diagram 11 on page 9 of Drawings of Installation, Use and Maintenance manual)
DURING INSTALL ROUTINE, DOOR WILL MOVE UP AND DOWN TWICE. WATCH THE MOVING
DOOR AND KEEP PEOPLE, AND OBJECTS AWAY FROM THE DOOR UNTIL IT IS COMPLETELY
CLOSED. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR!
(see Diagram 12 on page 9 of Drawings of Installation, Use and Maintenance manual)

Performing Install Routine

Detent Pin adjustment

11

Advertisement

Table of Contents
loading

This manual is also suitable for:

DiffusionPrestige+/40mm/pinnacleConfort

Table of Contents