Light Fixture Installation; Electrical Connections; Wall Station Security Code Change And Programming - Wayne-Dalton Optimal Installation, User Operation & Maintenance Manual

Table of Contents

Advertisement

7
Select a lamp socket, preferably located on the ceiling and within 2m of the opener. If none is available, have one installed by a
Tools Needed:
qualified electrician.
None
The light fixture must be attached to a properly installed and grounded 230 Volt AC lamp socket. Failure to use a properly
grounded lamp socket, may involve risk of electrical shock. If in doubt contact a qualified electrician.
NOTE: Door must clear light fixture when the door is open. There must be no obstructions between the light fixture and the
opener for the light fixture to work properly.
Insert a 75 W maximum light bulb (1t) into the light fixture. Orient light fixture with the lamp socket (1u) and screw in the light
fixture. Rotate light fixture's base (1v) to align the receiving module (1p) with the sending LED (1w) on the opener (1x).
If mounting the light fixture into a wall mounted lamp socket, the light fixture's receiving module will need to be adjusted from its
factory oriented position. Rotate receiver module (1p) outward 90 degrees until module snaps into position. Rotate light fixture's
base (1v) and receiver module holder to align receiving module (1p) with sending LED (1w) on opener (1x).
Final adjustment of the light fixture to the opener may be needed once the opener is electrically connected.
8
Tools Needed:
WARNING
None
NOTE: Make sure there are no obstructions that may interfere with the garage door during operation, prior to electrically
connecting the opener.
Locate power cord (1y) exiting right side of door header angle (1h). Route power cord to nearest convenient power outlet and
plug in power cord. (If the power cord is not long enough to reach the closest outlet, contact a service professional for further
options). As soon as power is applied to opener (1x), light fixture should light up and opener should beep twice. If the light
fixture does not light, adjust the receiver module on the light fixture, then remove power from opener and reapply power.
Repeat until the light comes on. Refer to Step 7, light Fixture installation.
Wall Station Security Code Change and Programming (If supplied,
9
NOTE: If the Wall Station is not supplied, skip this step and go to the step 10: Transmitter Security Code Change and
Tools Needed:
Programming.
None
NOTE: The user must change the wall station's security code before using the wall station. This code setting sequence is only
required the first time the wall station is used.
CHANGING THE WALL STATION'S SECURITY CODE:
Press and hold the wall station's light button (1z) for approximately 10 seconds until the wall station's LED (2a) begins to blink
rapidly. Once the LED (2a) starts blinking release the wall station's light button (1z); the LED (2a) will turn off. Immediately
press and hold the wall station's light button (1z) again (LED will light) for approximately 5 seconds. After approximately 5
seconds the LED (2a) will begin to blink on and off. Release the light button (1z). The wall station's LED (2a) will blink on and
off three times indicating a successful security code change. The wall station is now ready to be programmed to the opener.
Light Fixture Installation (If supplied, according to the model)
(see Diagram 7 on page 7 of Drawings of Installation, Use and Maintenance manual)
(see Diagram 8 on page 8 of Drawings of Installation, Use and Maintenance manual)
TO REDUCE THE RISK OF ELECTRICAL SHOCK, CONNECT POWER CORD ONLY TO A
PROPERLY GROUNDED 230 VOLTS OUTLET. DO NOT USE AN EXTENSION CORD OR CHANGE
PLUG IN ANY WAY. IF IN DOUBT CONTACT A QUALIFIED ELECTRICIAN.
(see Diagram 9 on page 8 of Drawings of Installation, Use and Maintenance manual)

Electrical Connections

according to the model)
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

DiffusionPrestige+/40mm/pinnacleConfort

Table of Contents