Skyjack SJ 8831E Maintenance And Parts Manual page 64

Dc electric full-size rough terrain
Hide thumbs Also See for SJ 8831E:
Table of Contents

Advertisement

Sevcontroller Adjustment And Diagnostics (Continued)
Table 5-4B. Sevcontrol Adjustable Parameters (Software Revision .10)
SEQ. NO.
IMAX
1
Maximum Controller Current
ACCEL
2
Acceleration Delay
DECEL
3
Deceleration Delay
CREEP
4
Maximum Controller Current
MAX
5
Maximum Allowed Speed
ELEVA
6
Elevated Cutback Speed
TILT
7
Tilted Cutback Speed
CONSTANT SPEED CONTROL
8
Proportional Gain (Do Not Adjust)
CONSTANT SPEED CONTROL
9
Integral Gain (Do Not Adjust)
BATTERY
10
Low Battery Cut-out
11
12
ELEVATED CURRENT
13
Max. Current When Elevated
BRAKE
14
Brake Personality Timer
NOTE:
Skyjack does NOT recommend exceeding the default settings.
Before making any adjustments, you must determine the revision of your software. When the
calibrator is plugged in, turn the power on and push and hold down the "-" button for 5 seconds.
SJ-800 Series E Battery Powered
119153
PARAMETER
WARNING
MIN.
MAX.
50
600
1.0
3.0
0.1
3.0
0
10
% of Max. Speed
5
100
% of Max. Possible Speed
5
25
% of Max. Speed
5
75
% of Max. Speed
0
150
1
100
25
40
Not Used
Not Used
50
400
0.0
3.0
UNITS
DEFAULT
Amps
400
Seconds
1.0
Seconds
0.1
2
80
15
50
Counts
30
Counts
20
Volts
25
Amps
230
Seconds
0.5
60286AA
SECTION 5, Page 13

Advertisement

Table of Contents
loading