Fault Tracing; Ordering Of Spare Parts - ESAB ORIGO Mig C280 PRO Instruction Manual

Table of Contents

Advertisement

GB
7

FAULT TRACING

Try these recommended checks and inspections before sending for an authorised
service technican.
Type of fault
No arc
Welding current is interrupted
during welding
Thermal overload trips
operate frequently
Poor welding performance
8

ORDERING OF SPARE PARTS

Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
Mig C280 PRO, Mig C340 PRO is designed and tested in accordance with the interna­
tional and European standards 60974-1, 60974-5 and 60974-10 . It is the obligation of
the service unit which has carried out the service or repair work to make sure that the
product still conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
bc23de
Actions
S
Check that the mains power supply switch is turned on.
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that correct current value is set.
S
Check whether the thermal overload trip has operated
(indicated by the orange lamp on the front).
S
Check the main power supply fuses.
S
Check to see whether the air filters are clogged.
S
Make sure that you are not exceeding the rated data for the
power source (i.e. that the unit is not being overloaded).
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that the correct current value is set.
S
Check that the correct welding wires are being used.
S
Check the main power supply fuses.
S
Check the wire feed unit - if proper rolls are applied and
properly set the pressure of the wire feeder's pressure rollers
- 15 -
© ESAB AB 2011

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Origo mig c340 pro

Table of Contents