Page 1
SP-900 LKW-Splitklimaanlage 107 Split airconditioning voor vrachtwagens Einbauanleitung Montagehandleiding HGV split air conditioner DA 126 Splitklimaanlæg til lastbiler Installation manual Installationsvejledning Climatiseur split pour poids lourds 145 Split-klimatanläggning för lastbilar Notice de montage Monteringsanvisning Equipo de aire acondicionado Split para...
Safety instructions CoolAir Using the device Only use the air conditioner for the purpose specified by the manufacturer and do not make any alterations or structural changes to the device. Only operate the air conditioner if you are certain that the housing and the cables are not damaged.
The manufacturer assumes no liability for non-observance of this installation manual. Any claims are excluded in this case. The operating manual for the CoolAir SP-900 is included in the air condi- tioner's scope of delivery. Target group...
Supplementary information on the product. Proper use The CoolAir SP-900 is for supplying the cab of a lorry with cooled and dehumidified air. It can be used while driving. Caution The CoolAir SP-900 is not suitable for installation in agricultural machines and construction machines or similar equipment.
Scope of delivery CoolAir Scope of delivery CoolAir SP-900 Part designation Quantity Item no. CoolAir SP-900 air conditioning unit 9100100002 consisting of: - Condenser unit 4442700183 - Evaporator unit with connection line 4442700184 Remote control (incl. type CR2025 battery) 4441600084...
The supplied assembly parts must not be modified during installation. If a WAECO fastening frame is not used to install the system, make sure that the installation position of the condenser unit on the rear panel is not too low.
Installation CoolAir Installation steps Caution The manufacturer only assumes liability for parts included in the scope of delivery. The validity of the warranty expires if the system is installed together with third-party parts. 5.3.1 Determining the installation position The system's installation position must meet the following criteria: The installation position must be chosen so that maintenance work can be performed without difficulties and so that there is sufficient space for the add-on parts (refrigerant line).
Installation CoolAir 5.3.2 Installing the condenser unit To install the condenser unit using a vehicle-specific WAECO fastening frame, please observe the instructions included in the frame's scope of delivery. The following work steps describe the installation of the con- denser unit without vehicle-specific fastening frame.
Installation CoolAir 5.3.3 Installing the evaporator unit The evaporator unit is fitted on the vertical rear panel, near the bunk, in a horizontal position: ➤ Remove the panelling from the evaporator unit (see Fig. 6 on page 5). ➤ Find a suitable fastening position in the cab that allows sufficient air circulation.
Installation CoolAir 5.3.4 Connecting the condenser unit to the evaporator unit Caution Avoid narrow radii during bending. Use a suitable round object as a bending aid. If the radius is too narrow, the refrigerant line will be kinked and the air conditioner would not be ready for operation. Caution Before fastening the connection couplings, make sure that the sealing and thread faces are absolutely clean.
Page 20
Installation CoolAir The connection lines should be installed at right angles to the rear panel of the lorry (see Fig. 12 on page 7). For this purpose, use body adhesive (e.g. Betalink K1) and a self-tapping screw to fasten the holders (see Fig. 13 on page 7).
➤ Insert the plug of the power cable in the socket of the roof air conditioner. ➤ Use a cable tie to protect the power cable from rubbing and damage. ➤ After completing the installation, switch on the CoolAir SP-900 and check the start of the compressor.
Installation CoolAir Check the voltage drop between the vehicle connection and the cable connector on the compressor. The voltage drop must not exceed 0.5 V. ➤ Use the previously removed hex screws to fasten the housing of the condenser unit. 5.3.6 Sealing and attaching the cover ➤...
Configuration CoolAir Configuration Before you first start up the system, you can adapt the controls according to the installation conditions. This must be done by the person installing the system. In configuration mode, the following system software parameters must be set at the control panel (see Fig.
Configuration CoolAir Menu level 1: Set temperature The system always starts with a defined value for the room temperature. This parameter can be configured between 17 and 30 °C: ➤ Start configuration mode (see chapter “Starting and ending configura- tion mode” on page 43). ✓...
Configuration CoolAir ➤ Use the Temp. + and - buttons (fig. 184 or 5) to select the low voltage cut-off value. The characteristic figures at second and third place on the digital display represent the voltage (V) at which the system is shut down: Charac- Charac-...
Configuration CoolAir Menu level 4: Default setting You can reset the parameters you set in configuration mode at menu levels 1 to 3 to the default settings: ➤ Start configuration mode (see chapter “Starting and ending configura- tion mode” on page 43). ✓...
Maintenance and care CoolAir Maintenance and care Caution Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the device. Condenser unit ➤ Clean the condenser unit at least once every season, ideally at the beginning of the season.
Technical data CoolAir Technical data CoolAir SP-900 air conditioner Item number 9100100002 Cooling capacity: 900 W Rated input voltage: 24 V DC Input voltage range: 20 V DC – 30 V DC Operating temperature range: 0 – 43 °C Current consumption: 12 –...
Need help?
Do you have a question about the Coolair SP-900 and is the answer not in the manual?
Questions and answers