KLING & FREITAG CA 106 User Manual

KLING & FREITAG CA 106 User Manual

Hide thumbs Also See for CA 106:

Advertisement

Quick Links

K&F CA 106
Die Version CA 106 F weicht in Form und Aussehen von
User's Manual
Benutzerhandbuch
Important Information,
Please Read Before Use!
KLING & FREITAG GmbH
Junkersstrasse 14
D-30179 Hannover
PHONE +49 (0) 511- 96 99 70
TEL 0 (049) 511- 969 97-0
FAX
+49 (0) 511- 67 37 94
www.kling-freitag.de
dieser Abbildung ab.
Released: 08.11.2006
Stand: 08.06.2006
Version 5.1.
Version 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CA 106 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KLING & FREITAG CA 106

  • Page 1 K&F CA 106 Die Version CA 106 F weicht in Form und Aussehen von dieser Abbildung ab. Version 5.1. Version 1.0 User‘s Manual Benutzerhandbuch Released: 08.11.2006 Stand: 08.06.2006 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstrasse 14...
  • Page 2: User's Manual Ca

    User's Manual CA 106 KLING & FREITAG GMBH ©1995 - 2006 Version 5.1, 09.11.2006 Page 2 of 26...
  • Page 3 With the purchase of a CA 106 System, you have acquired a speaker system with the highest possible quality and performance capabilities. As the owner of this system, you now have a versatile and highly professional tool which, when operated properly, is a true pleasure to use.
  • Page 4: Table Of Contents

    9.2.1 Full-Range Mode with K&F C2 Controller 9.2.2 CA 106 & Bass with Controller C2 in 2-Way Active Mode 10. Operating the Speakers 11. Crossover: Wiring Diagram CA 106 12. Touching Up Damage to Paint / Changing the Front Foam 13.
  • Page 5: General Safety Instructions For Using Speakers

    User's Manual CA 106 1. General Safety Instructions for Using Speakers Mounting the speakers To prevent injury, this equipment must be securely placed on the floor or secured to the wall according to the mounting instructions on page 10 ( Mounting Instructions for Loudspeakers ).
  • Page 6: Preventing Hearing Damage

    User's Manual CA 106 The following signals may damage the speakers − permanent high-pitched signals with high frequency and continuous noise from feedback. − permanently distorted signals with high power . − noises, which occur when the amplifier is on while equipment is being con- Important nected, disconnected or switched on .
  • Page 7: Ca 106 Product Descriptions And Versions

    Its discreet design also makes the CA 106 suitable for fixed installations. Special versions: − CA 106-100V: Version with 100V / 50 VA / 100 VA / 150VA toroidal transformer − CA 106 ‘Outdoor Installation' − CA 106 ‘Outdoor 'Mobile' −...
  • Page 8: Instructions For Versions With '100 V' Option

    4.2 Connecting Diagram of the 100V Speaker Inputs The 100 V transformer for the CA 106 has 3 taps. These enable the speaker to be oper- ated at 50 VA, 100 VA or 150 VA. Which tap is connected to which pin can be seen below.
  • Page 9: Coverage Angles Of The Ca 106 Speaker

    6. Coverage Angles of the CA 106 Speaker The CA 106 can be operated in a vertical or horizontal (i.e. as a stage monitor) posi- tion. The coverage pattern of the speaker can be adapted to special needs by a 90°...
  • Page 10: Mounting Instructions For Loudspeakers

    The following graphics will assist in making a rough estimate as to the distance range of the CA 106. The graphics only take into consideration the sum of the direct sound and not the influence of the room. Because of this there can, in some cases, be noticeable deviation.
  • Page 11: Arrayed Speaker Systems (Cluster)

    User's Manual CA 106 7.2 Arrayed Speaker Systems (Cluster) If the loudspeakers are operated through the optional K&F C2 System Controller, we recommend turning on the ‘Top Low Cut’ switch for clustered operation. Thus the fre- quency response for this application can be optimised (see also K&F C2 User's Manual).
  • Page 12: Wiring

    The speaker is equipped with two parallel Speakon connectors. Make sure that all units are switched off and all controls are turned down before con- necting your CA 106 systems. − We recommend the use of high-quality speaker cables provided by KLING & FREITAG.
  • Page 13: Avoiding Ground Loops

    Avoiding Ground Loops Avoiding Ground Loops If there is a loud humming or buzzing after the CA 106 System has been connected, then check that a "ground loop" has not been built into the system. Some power am- plifiers and system controllers are equipped with a "Ground Lift" switch. Set these swit- ches to the "Lift"...
  • Page 14: Configurations And Connecting Diagrams

    9. Configurations and Connecting Diagrams 9.1 Operating the Systems without C2 Controller The CA 106 systems can be used alone or in conjunction with a K&F subwoofer with integrated crossover (e.g. SW 112-XO / SW 115D-XO / SW 115E - XO or SW 118E-XO).
  • Page 15: Full Range Mode & Subwoofer With Crossover (Xo)

    Switch on the subwoofer’s connecting terminal When using the CA 106 systems in a cluster (speakers in close proximity), reduce the frequencies below 300 Hz by 3-4 dB. (The K&F C2 Controller is equipped with a special filter for this purpose, which can be activated by pressing the "Top-Low Cut"...
  • Page 16: Operations With C2 Controller

    User's Manual CA 106 9.2 Operations with C2 Controller By using carefully adjusted filters (EQ) on special system cards for the CA systems, the C2 Controller optimises feedback prevention and the frequency response of the spea- kers. The controller provides optional bass boost in full-range mode, optimisation for cluster operation (Top-Low Cut switch), high boost and sub-mono function.
  • Page 17: Full-Range Mode With K&F C2 Controller

    User's Manual CA 106 9.2.1 Full Full- - - - Range Mode with K&F C2 Controller Range Mode with K&F C2 Controller Full Full Range Mode with K&F C2 Controller Range Mode with K&F C2 Controller LINK, e.g. to next controller...
  • Page 18: Ca 106 & Bass With Controller C2 In 2-Way Active Mode

    Recommended combinations of CA 106 Systems with K&F subwoofers in 2-way active mode with C2 Controller: 2-4 x CA 106 via C2 Controller with 1-2 x SW(i) 112 or 1 x SW(i) 115D - XO or 1 x SW(i) 115E - XO or 1 x SW(i) 118E - XO...
  • Page 19: Operating The Speakers

    Now put a low level signal into the system and check for the correct function of the system. In doing so, all amplifier input controls need to be turned off again. Now turn on the control for the left CA 106 system and check that the correct signal is coming out of the CA 106 system.
  • Page 20: Crossover: Wiring Diagram Ca 106

    User's Manual CA 106 11. Crossover: Wiring Diagram CA 106 Pin assignment Speakon NL4 ‘IN’ 1+ 1- 2+ 2- ‘OUT’ parallel with ‘IN’ 12. Touching Up Damage to Paint / Changing the Front Foam Although the PU structured paint used by KLING & FREITAG is impact proof and ex- tremely resistant, we recommend using protective coverings or cases to help avoid da- maging the paint during i.e.
  • Page 21: Technical Specifications

    User's Manual CA 106 13. Technical Specifications Loudspeaker Design 2-way passive system, bass reflex tuning Frequency range -10 dB 78 Hz - 22 kHz Frequency range ±3 dB 88 Hz - 20 kHz Coverage angles (nominal) 90° x 60° (hor. x vert.) Directivity index (DI) 10 (+1.5/-2) 1.5 kHz - 15 kHz...
  • Page 22: Measuring Charts

    User's Manual CA 106 14. Measuring Charts Frequency response Frequency response Impedance 3,16 1000 10000 20000 Frequency (Hz) Horizontal Beamwidth Vertical 1000 10000 20000 Frequency (Hz) Directivity 1000 10000 20000 Frequency (Hz) KLING & FREITAG GMBH ©1995 - 2006 Version 5.1, 09.11.2006...
  • Page 23 User's Manual CA 106 Horizontal coverage 180° 150° 120° 90° 60° Attenuation (dB) 30° < 3 0° 3 - 6 -30° 6 - 9 -60° 9 - 12 -90° 12 - 15 -120° 15 - 18 -150° > 18 -180°...
  • Page 24: Dimensions

    User's Manual CA 106 15. Dimensions KLING & FREITAG GMBH ©1995 - 2006 Version 5.1, 09.11.2006 Page 24 of 26...
  • Page 25: Accessories

    User's Manual CA 106 16. Accessories CA 106 cluster plate Application example for CA 106 plate Adjustable speaker mount CA 106 U-mount wall / ceiling bracket CA 106 Wall and ceiling mount ‘Omnimount’ mounting adapter TV-spigot adapter Pipe Clamp TV-spigot...
  • Page 26: Regulations For Disposal

    User's Manual CA 106 17. Regulations for Disposal 17.1 Germany: It is not allowed to dispose of used electrical equipment as domestic waste. But please do not dispose of them at official collecting points for recycling either! All Kling & Freitag products are plain business-to-business (B2B) products. Disposal of Kling &...

Table of Contents