Read, Read Reverse, or Space Blocks command. This is most noticeable when the
host sends a command to read one block while the tape is at BOT, or to read one
block in the opposite direction (i.e., read reverse after a read forward operation). If
read-ahead is enabled, the drive will continue to move the tape and read blocks into
the buffer until the buffer is full. If read-ahead is disabled, the drive will move only
the amount of tape required to read one block into the buffer.
The read-ahead operation is transparent to the host, and is not available during
write operations.
- The read-ahead operation is disabled;
OFF
- The read-ahead operation is enabled for any Read or Space command,
1 FMK
and ends either when the buffer is full or when one filemark is encountered. The
read-ahead operation will resume when a Read, Read Reverse, or Space
command is processed after the filemark is transferred to the host;
- The read-ahead operation is enabled for any Read or Space command.,
2 FMK
and ends either when the buffer is full or when two sequential filemarks are
read. The read-ahead operation will resume when a Read, Read Reverse, or
Space command is processed after the two sequential filemarks are transferred
to the host. Note that two sequential filemarks usually indicate logical EOT.
5.1.25

Read CER (Default = Ignore)

This parameter allows you to inhibit the reporting of correctable errors (CERs)
during read operations.
IGNORE
read error occurs;
REPORT
read error occurs.
In both cases, corrected data is sent to the host. An Incorrect Length Indicator (ILI)
may accompany the Recoverable Error Check Condition.
5.1.26

Read HER (Default = Report)

The Read HER parameter allows you to inhibit the reporting of hard errors and to
disable retries during read operations.
REPORT
IGNORE
5.1.27

Read Retrys

This parameter lets you set the number of automatic retries the drive will perform
when it detects a hard error during a read operation. If the error occurs, the drive
5-12
- The drive will not report a Recoverable Error Check Condition when a
- The drive will report a Recoverable Error Check Condition when a
- Report hard errors as media errors.
- Do not report hard errors and do not perform retries.
SCSI Configuration