Optional Light Installation - Regency Fireplace Products Horizon HZ42E-NG Owners & Installation Manual

Horizon hz42e series gas fireplace
Table of Contents

Advertisement

1
2
2
1
1
Plug Wiring
Amber Glass
Important: 120 Volt AC power is required for the optional light.
The receptacle box will be installed on the lower left corner of
the unit and will need to be wired by a qualifi ed electrician prior
to the optional light installation. The neutral (wider) slot of the
polarized receptacle should be at the top. A wall mounted switch
should be installed to turn the accent lighting on/off.
See wiring diagram in the instruction manual.
1) Shut off electrical supply.
If faceplate is already installed - follow steps 2 & 3.
2) Remove faceplate by lifting up off glass door - see below.
3) Slide out bottom faceplate panel - see below.
m
l
e
d
n
Faceplate
HZ42E Regency Horizon™ Gas Fireplace

OPTIONAL LIGHT INSTALLATION

HZ42 Accent Light Assembly Kit # 596-959
910-814
Plug wiring + gasket
910-997
Halogen Bulb
940-363
Amber Glass
Light Assembly
Includes gaskets (x2)
918-828
Instruction Sheet
Bottom
Faceplate Panel
4) Remove the glass door - see instructions in manual.
5) Remove the glass crystals/optional ceramic stones or pebbles- if
installed.
6) Remove the inner panels if installed - see instructions in manual.
7) Remove the bottom cover - shown below.
Light Diffuser
8) Loosen the 3 screws securing burner - slide burner to the left
and lift out - shown below.
Glass Door
9) Remove cover plate located on the left side of the fi rebox fl oor
by removing 4 screws. Discard the cover plate and gasket - keep
the screws.
Cover
Plate
INSTALLATION
Bottom Cover
Burner
41