Safety Label; Copy Of Safety Decal - Regency Fireplace Products Horizon HZ42E-NG Owners & Installation Manual

Horizon hz42e series gas fireplace
Table of Contents

Advertisement

This is a copy of the label that accompanies each HZ42E-NG and HZ42E-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for
your review.
NOTE: Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Listed:
Certified for/Certifi e pour:
Tested to:
4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
NATURAL GAS: Model HZ42E-NG
Minimum supply pressure
5.0"
Manifold pressure high
3.5"
Manifold pressure low
1.6"
Orifice size
#40
Minimum input
17,500 Btu/h
Maximum input
26,000 Btu/h
Altitude
0-4500
PROPANE GAS: Model HZ42E-LP
Minimum supply pressure
12" WC
Manifold pressure high
10"
Manifold pressure low
6.4"
Orifice size
#53
Minimum input
19,500 Btu/h
Maximum input
24,500 Btu/h
Altitude
0-4500
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
HZ42E Regency Horizon™ Gas Fireplace

COPY OF SAFETY DECAL

VENTED GAS FIREPLACE HEATER /
é
CANADA and U.S.A.
CAN/CGA-2.17-M91,ANSI Z21.88a-2007/CSA 2.33a-2007
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le HZ42E
Pression d'allimentation minimum
WC/C.E.
(1.25kPa)
Pression à la tubulure d' chappement lev e
WC/C.E.
(0.87kPa)
Pression à la tubulure d' chappement basse
WC/C.E.
(0.40kPa)
Grandeur de l'injecteur
DMS
D bit
é
Calorifique
(5.13 kW)
D bit
é
Calorifique
(7.62 kW)
l'altitude
ft/pi
(0-1372 m)
É
QUIP A L'UISINE POUR GAZ PROPANE
É
CONCU POUR ETRE POELE: Mod le HZ42E
Pression d'allimentation minimum
(2.98 kpa)
Pression à la tubulure d' chappement lev e
WC/C.E.
(2..49kPa)
Pression à la tubulure d' chappement basse
WC/C.E.
(1.60kPa)
Grandeur de l'injecteur
DMS
D bit
é
Calorifique
(5.71 kW)
D bit
é
Calorifique
(7.18 kW)
l'altitude
ft/pi
(0-1372 m)
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
FOYER AU GAZ À ÉVACUATION
é
é
é
é
é
minimum selon
maximum selon
é
é
é
é
é
minimum selon
maximum selon
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
FPI Fireplace Products International Ltd. Delta, BC, Canada

SAFETY LABEL

Serial No./ No de serie
371
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Side Walls
A
B
Ceiling
D
F
B
Min. Mantel Height
A
C
C
Max. Mantel Depth
D
Alcove Width
E
E
Alcove Depth
F
DOOR SEAL: Please
check that the door is
properly sealed
(See Instruction Manual for
detailed instructions)
Made in Canada/ Fabrique au Canada
8" (203mm)
22" (559mm)
13" (330mm)
13" (330mm)
84" (2133mm)
36" (914mm)