Horizontal Terminations; Flex Vent 4" X 6-5/8 - Regency Fireplace Products Horizon HZ42E-NG Owners & Installation Manual

Horizon hz42e series gas fireplace
Table of Contents

Advertisement

INSTALLATION
These venting systems, in combination with the HZ42E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the HZ42E using a fl exible vent.
FPI Kit #
Length
Contains:
#946-513
2 Feet
1)
2)
3)
4)
#946-515
4 Feet
5)
6)
7)
8)
#946-516
10 Feet
9)
Notes:
1) Liner sections should be continuous without any
joints or seams.
2) Only Flex pipe purchased from Regency
used for Flex installations
3) Horizontal vent must be supported every 3 feet.
®
4) Regency
Direct Vent System (Flex) is only approved
for horizontal terminations.
5) Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
22

HORIZONTAL TERMINATIONS

FLEX VENT 4" X 6-5/8

6-5/8" fl exible outer liner (Kit length)
4" fl exible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
®
may be
"
HZ42E Regency Horizon™ Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz42e-lp

Table of Contents