Telephone Communicator Testing; System Testing; Battery Replacement - jablotron JA-63 User Manual

Hide thumbs Also See for JA-63:
Table of Contents

Advertisement

Example: to store tel. number 0 123456 to memory no. 2 enter: 7 0 F0 12345 F2
To delete a telephone number enter:
7 F0 Fy
where y is a memory number from 1 to 4
To exit user mode, press the N key.
5.2.2

Telephone communicator testing

Testing is possible in the user mode. To switch the control panel to the user
mode enter F 0 master code. User mode will be indicated by a U on the keypad.
Entering 89 will cause the communicator to send voice message number 2 to all
programmed telephone numbers. It will also send an SMS message if
programmed. The telephone line signals will be audible from the control panel's
built in speaker during the test (if the dialer is triggered by an alarm in normal
operation, it will call silently). Testing can be terminated with the N key.
Notify the people who will be called before testing!
To exit user mode, press the N key.

6 System testing

The supervisor should test the system monthly. For testing the control panel
should be in the user mode. Enter F0 master code to switch to the user mode (U
will be indicated on the keypad).
No alarm can be triggered while in the user mode and any triggering of a
detector, a remote control or a panic button will be indicated on the keypad.
Note: some detectors (for example the wireless motion detector) in normal mode can not
send the next triggering information until 5 minutes after the previous triggering was sent. It
is possible to switch such a detector to the testing mode by opening and closing its cover.
See the particular product manual for more details.
If anything does not work during testing, call the installer.
To exit user mode press N.

7 Battery replacement

All the battery-powered items perform regular battery testing. If the lifetime of the
battery is near the end, the system will indicate the need for battery replacement
(Battery indicator and the item address will be shown on the keypad).
When any detector or keypad asks for new batteries, they should be replaced in
a week. To replace batteries either call the installer or do the following:
switch the control panel to the user mode (entering F0 master code)
Alarm system JA-63 „Profi"
- 12 -
MGK51504

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents