The auto-reverse function should be regularly inspected and adjusted if necessary. Once
this step is complete, replace the cover and install the rubber caps over the screws.
(VR1) Over-current Sensitivity:
The range of Over-Current resistance can be adjusted between 3.5
amperes and 7 amperes by turning the screw.
(VR2) Close Delay
The SM2 (slave leaf) start delay can be adjusted between 0 seconds and 8
seconds by turning the screw.

DIP Switches

Auto-close function
This feature allows the gate to stay open for 15, 25, or 50 seconds before it automatically
closes. Combine settings on switches 4 and 5 to create the following gate open/close
situations:
DIP4 (Auto close1)
OFF
OFF
ON
ON
DIP5 (Auto close2)
OFF
ON
OFF
ON
page 32
Function
No auto close/Auto close OFF
Auto close On, waiting time 50 seconds
Auto close On, waiting time 25 seconds
Auto close On, waiting time 12 seconds