Pull to Open Inward
Pull to Open is the most common configuration for an entry gate.
Opening Angle
A cm
90
17.5
110
18
The installation should meet the specifications shown above. Failure to do so may cause
opening and closing problems.
This configuration pulls your gate open, into
your property, to open.
Mount the actuators on the included brackets
according to the figure below. The gate mounts
on one face of the mounting post, and the opener
mounts on the face 90 degrees from it.
Mount the actuator so that the key slot is on top
of the arm. Open the gate and lock the actuator
with the key.
A inch
B cm
B inch
6.88
14.5
5.7
7.08
9.5
3.74
page 16
C cm
C inch
D cm
117.8
46.38
6.5
118.3
46.57
6.5
D inch
2.56
2.56