SpectraLink Corporation
UL Information
This symbol on the nameplate means the product is listed by Underwriter's Laboratories, Inc. It
is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire,
casualty, and electrical hazards.
The following are statements required for UL certification, related to safety procedures that must be
adhered to during installation.
Follow these general precautions while installing telephone equipment:
•
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
•
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
•
Use caution when installing or modifying telephone lines.
When installing Base Stations outside or in buildings other than the one containing the System Controller,
take the following precaution:
If wiring for a Base Station exits a building—whether to reach an outdoor Base Station location or to reach
a Base Station in another building—the wiring must be protected at both ends by a Quick Clip Fuse from
Illinois Tool Works, Linx Division, model number SCP-2X2. The Quick Clip Fuse replaces the bridging
clips on the 66 blocks for all four connections to the non-internal Base Station.
Page ii
Link 150 M2 Installation and Operation
08/11/99