No representation or other affirmation of fact contained in this document including but not limited to statements regarding capacity, response-time performance, suitability for use, or performance of products described herein shall be deemed to be a warranty by SpectraLink for any purpose, or give rise to any liability of SpectraLink whatsoever.
Page 3
Note concerning shielded cable: SpectraLink recommends the use of shielded cable for all external signal connections in order to maintain FCC Part 15 emissions requirements. Note concerning the Wireless Telephone and Base Stations: This device complies with Part 15 of the FCC Rules.
Page 4
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU UL Information This symbol on the nameplate means the product is listed by Underwriter’s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire, casualty, and electrical hazards.
If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service. If you experience trouble with this telephone equipment, please contact SpectraLink Corporation for information on obtaining service or repairs.
Page 6
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Industry Canada (IC) Notice Notice: The Industry Canada (IC) label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s).
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Table of Contents 1. ABOUT THIS DOCUMENT Contacting SpectraLink Icons Used in this Document Remote Installation Overview Remote Installation Steps (Overview) 2. SITE PREPARATION Required Materials Provided by Customer...
This document explains installation of the SpectraLink Link Wireless Telephone System (Link WTS, MCS300) Remote T1 Module. The installation process connects the Link 3000 MCU Primary Shelf in one location with an Expansion Shelf in a remote location, via T1 facilities.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Remote Installation Overview Networking the Link WTS allows installation of expansion shelves at remote locations. T1 circuits are used to provide the connection from the System Controller shelf to each Remote Expansion shelf.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Remote Installation Steps (Overview) Follow these steps to install the T1 Remote Module. Detailed instructions for each of these steps are contained in this document and other relevant documents in the Link 3000 MCU System Documentation.
Rack measures 15” high by 19” wide by 9” deep, and weighs approximately 35 pounds fully loaded. See Prepare Location for Shelves, in the Link WTS – Link 3000 MCU: Installation document. – as an alternative to rack mounting, the shelves can be wall Backboard space mounted to ¾”...
T1 circuits must be 64Kbps (not 56Kbps) per channel. Line coding for the T1 circuits must be Bipolar 8-bit Zero Substitution (B8ZS). T1 circuits should be terminated as close to the Link 3000 MCU shelves as possible, at both the System Controller site and the Expansion Controller site(s).
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Check Components The following items should be at the installation site. – (MCS300) – the number of shelves varies Link 3000 MCU Expansion Shelves depending on the size of the system.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 3. Install T1 Remote Module at Local Site Before installing the hardware at the remote site, the Primary shelf at the local site must have a T1 Remote Module (CRC301) installed. Install one Remote Module for each remote shelf to be installed.
Page 15
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Network Clocked T1 Facilities If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as the Master Clock Source. Connect the port on this T1 Remote Module to...
Page 16
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU CRC-301 TIMING MASTER SYNC To AUX Port on Intershelf Junction Panel for Net Clocked T1 ALARM SYSTEM CONTROLLER RJ45 to Intershelf Junction Panel SC/A EXPANSION SHELF CONTROLLER SC/B...
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4. Install System at Remote Site Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes: • Location chosen for the shelves is adequate.
Connect Power to Shelves SpectraLink recommends that a licensed electrician install the –48V DC power supply and connect power to the shelves. See Link WTS – Link 3000 MCU: Installation, Connect Power to Shelves, for more information. Install Cards The shelf diagram below shows a fully loaded Expansion Shelf. Any type of Interface Module can be installed in slots 3-12.
Page 20
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU The following diagram shows the T1 Remote Module connections at the REMOTE site. CRC-301 TIMING MASTER SYNC From sync "Out" if more than one remote shelf To sync "In" if more...
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Connect Demarc Block RJ-21 Cables to Interface Modules Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector ( ) on each Interface Module. Secure the cables using the keeper.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5. Configure Remote System Use the Operator’s Console to enter configuration information for the Remote Expansion Shelves. Configure Remote Shelf 1. From the Operator’s Console, select F1, Supervisor State Display 2.
SAVE Test System The system should now be tested to ensure that it is functioning correctly. See Test System in the Link WTS – Link 3000 MCU: Installation manual for more information. Part Number: 72-0059-06-E.doc Page 23...
T1 Remote Module Installation Link WTS – Link 3000 MCU 6. Site Certification The installer should not leave the site before contacting SpectraLink to perform remote install verification. Before leaving the location where the Primary Shelf is installed, the installer must complete the following items: From the Operator’s Console, copy the PCS.CFG file to diskette.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7. Installation Forms This section contains the following forms: Base Station Locations Extension Assignments Site Preparation Checklist Customer Acceptance Form Copy these forms as needed. Be sure to maintain completed forms for future reference.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Base Station Location Form Shelf Number: ________ Interface Module: ________ Location Interface Base Station # (e.g.: building, floor #, detailed description) Module Circuit # Base Station 1 Base Station 2...
Link WTS – Link 3000 MCU Site Preparation Checklist If upon arrival the SpectraLink installer determines that the pre-installation work has not been completed correctly, the installer has two options: 1) the installer can leave the site and reschedule the installation when the action items have been completed or corrected, or 2) the installer can assist in preparing the site, and thus spend additional time installing the system.
Description & Serial Number The terms and conditions of original Quotation and Sales Agreement apply to all equipment listed above. _____ I accept the installation of the SpectraLink system as complete. _____ I decline to installation of the SpectraLink system because:...
Page 30
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Index Base station location form, 27 Master Clock, 24 Cards Network Clocked T1, 16 Installing, 15, 19 Configuration, 23, 24 Channel Service Unit, 13 Power, 19 Configuration Requirements...