Summary of Contents for SpectraLink Link 150 M3 MCU

  • Page 1: Installation And Operation

    Link 150 M3 MCU Installation and Operation Link Wireless Telephone System Part Number: 72-0075-01 Issue F...
  • Page 2: Trademark Information

    No representation or other affirmation of fact contained in this document including but not limited to statements regarding capacity, response-time performance, suitability for use, or performance of products described herein shall be deemed to be a warranty by SpectraLink for any purpose, or give rise to any liability of SpectraLink whatsoever.
  • Page 3: Important Safety Information

    SpectraLink Corporation WARNING: Changes or modifications to this equipment not approved by SpectraLink Corporation may cause this equipment to not comply with part 15 of the FCC rules and void the user’s authority to operate this equipment. WARNING: SpectraLink products contain no user-serviceable parts inside. Refer servicing to qualified service personnel.
  • Page 4: Table Of Contents

    Icons and Conventions 2. Installation Overview Installation Steps and Responsibilities 3. Link Wireless Telephone System Overview System Operation The Front Panel of the Link 150 M3 MCU 4. Site Preparation Required Materials Determine Location of MCU 5. Run Cable for System...
  • Page 5 SpectraLink Corporation 12. Technical Parameters 12.1 Select Alternate Spread Spectrum Sequence 12.2 Change Companding PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Page 5...
  • Page 6: About This Document

    This document explains installation and operation of SpectraLink’s Link Wireless Telephone System (Link WTS), using the Link 150 Model 3 (M3) Master Control Unit (MCU). The Link 150 M3 MCU adds wireless service to your existing telephone system. The installation process connects the Link WTS to your telephone system, and activates the Link Wireless Telephones.
  • Page 7: Installation Overview

    1. Site preparation and wire installation: This is usually done by a wire technician or contractor. 2. Installing the SpectraLink system: This is done by SpectraLink or one of our certified distributors. 3. Programming the customer’s telephone system to work with the SpectraLink system: This is usually done by the customer’s system administrator or...
  • Page 8: Installation Steps And Responsibilities

    Install outdoor Base Stations Connect and register handsets Set up diagnostic modem Register handsets Program handset features Test handsets Site certification PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Wire Field Customer Contractor or Service Project Mgr/ Electrician Engineer...
  • Page 9: Link Wireless Telephone System Overview

    M3 MCUs can be linked together for extended coverage area. Chained MCUs support up to 64 handsets maximum. PN: 72-0075-01-F.doc Base Stations Master Control Unit Telephones Gateway Installation and Operation Link WTS – Link 150 M3 MCU Link Wireless Page 9...
  • Page 10 SpectraLink Corporation SpectraLink offers an analog MCU that works with telephone systems (CO, PBX or Key Systems) with analog (loop start) ports. We also offer digital MCUs that work with the most common brands of telephone systems’ (PBX or key systems) digital ports.
  • Page 11: The Front Panel Of The Link 150 M3 Mcu

    SpectraLink Corporation The Front Panel of the Link 150 M3 MCU The MCU’s front panel contains the connections to the telephone system, switches to control system administration, and status LEDs. PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU...
  • Page 12: Site Preparation

    Quick Clip Fuse Required with an RCO410 Outdoor Base Station or when a Base Station is located in a separate building from the Link 150 M3 MCU. Recommended Quick Clip Fuse is available from Illinois Tool Works, Linx Division, Model # SCP-2X2.
  • Page 13: Run Cable For System

    The Base Station locations should be designated on the building floor plans provided to the SpectraLink field service engineer. Base Stations can be mounted easily on raised or acoustical ceiling tiles, or on the wall. Avoid locating Base Stations in high or hard-to-reach places, as this will hinder maintenance, testing and/or repositioning.
  • Page 14: Terminate Cable At Base Station Locations

    To avoid damage to the connectors or crimps, be sure to run the wire to the Base Station before connecting the RJ-45 connectors. PN: 72-0075-01-F.doc RJ-45 Modular Cable Installation and Operation Link WTS – Link 150 M3 MCU Page 14...
  • Page 15: Prepare Demarc Blocks

    Panasonic (Universal 2-wire Auxiliary Digital) Executone (Universal 4-wire Auxiliary Digital) If the wiring between the Link 150 M3 MCU and the telephone system leaves the building, consult your telephone system manual for instructions on providing adequate lightning and other over-current protection. All MCUs (except the analog interface SCA-5XX) are intended only for connection to the isolated side of an on-premises telephone switch.
  • Page 16 Dedicated Line for Diagnostic Modem The Link 150 M3 MCU can be accessed remotely using an internal modem. To use the modem for remote access, a dedicated dial-in line must be provided. On digital interface systems this line must be terminated as a digital extension to the MCU.
  • Page 17 Data Pairs 20-23 Pair 24 & 25 Unused Four-wire Digital Connection PN: 72-0075-01-F.doc Receive (RX) To PBX Pair 1-16 Transmit (TX) From PBX Pair 1-16 Base Stn. 1-4 Base Stn.1-4 Installation and Operation Link WTS – Link 150 M3 MCU Page 17...
  • Page 18: Install Demarc Blocks

    For details, refer to the for the type of PBX in use at your location. PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Page 18...
  • Page 19: Connect Cables From Base Stations And Phone Lines To Demarc Blocks

    Photocopy the and provided in this manual as needed. Use the forms to track the Base Stations and handset port assignments connected to each MCU. As the SpectraLink field service engineer makes each Base Station or handset connection, fill in the information on the form to identify the position of the Base Station or handset (the building and floor number, for example) and a detailed description of the location (perhaps a room number).
  • Page 20 UNUSED Base 1 & 2 Station Power 3 & 4 Pairs Base Station Data Pairs UNUSED PN: 72-0075-01-F.doc Two-wire Connector Installation and Operation Link WTS – Link 150 M3 MCU 25 PAIR MALE CONNECTOR CABLE TO CONNECTOR A Page 20...
  • Page 21 3 & 4 Pairs Base Station Data Pairs Unused PN: 72-0075-01-F.doc on the MCU. They should be wired as Four-wire Connector A Installation and Operation Link WTS – Link 150 M3 MCU 25 PAIR MALE CONNECTOR CABLE TO CONNECTOR A Page 21...
  • Page 22 PN: 72-0075-01-F.doc ring ring ring ring ring ring ring ring ring ring ring ring ring ring ring ring Four-wire Connector B Installation and Operation Link WTS – Link 150 M3 MCU 25 PAIR MALE CONNECTOR CABLE TO CONNECTOR B Page 22...
  • Page 23: Install Link Wireless Telephone System

    Use only the provided Class II AC Adapter with output 24VDC, 1A. IPC Cable Each MCU is shipped with one inter-processor communication (IPC) cable to carry signals between Link 150 M3 MCU units. It is used only when multiple MCUs are chained together.
  • Page 24: Install Mcus

    Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector ( keeper. PN: 72-0075-01-F.doc ) on each MCU. Secure the cables using the Installation and Operation Link WTS – Link 150 M3 MCU Page 24...
  • Page 25 IPC IN IPC OUT IPC OUT CONN CONN CONN port of the first unit. An Open Installation and Operation Link WTS – Link 150 M3 MCU port of the STEP ADMIN NORMAL REGISTER DEL / ENTER IPC IN IPC OUT...
  • Page 26 LINE until the correct LEDs are lit. Use the LINE Installation and Operation Link WTS – Link 150 M3 MCU on the position. ERROR ). This should take less (indicating an LEDs will be lit.
  • Page 27 The SCX will only support Mitel. 1, 2, 4 SCU5xx SCU5xx SCP5xx The SCX will only support Panasonic. SCU5xx 2, 3 SCU5xx NORMAL STATUS Installation and Operation Link WTS – Link 150 M3 MCU Notes ) will LEDs . For Page 27...
  • Page 28: Install Base Stations

    Base Station. • If the LED turns solid red, there should be an error message on the MCU’s LEDs. Refer to section 9.1 Troubleshoot Error Codes. STATUS PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Page 28...
  • Page 29 1/3”, five full turns, into the Base Station. 4. If the ceiling is open with I-beams or pipe construction, mount the Base Station with I-beam clamps or pipe clamps. PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Page 29...
  • Page 30: Install Outdoor Base Stations

    4. Place the Base Station inside the enclosure with the part number label facing the back of the enclosure. 5. Screw the protective cover onto the Base Station enclosure. PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Page 30...
  • Page 31: Connect And Register Handsets

    Connect and Register Handsets Set Up Diagnostic Modem Each MCU has an internal modem feature that allows SpectraLink technicians to dial into the system for troubleshooting and maintenance. The modem is enabled on Line 1 when no handset is registered to Line 1. When enabled, the modem will auto- answer an incoming call to that line.
  • Page 32: Unregister Handsets

    These features can be accessed via the handset, but the telephone system or Link 150 M3 MCU must be programmed to allow access to these features from the handset. For information on programming the switch to operate with the handsets, refer to for your PBX PN: 72-0075-01-F.doc...
  • Page 33: Test Handsets

    SpectraLink Corporation • If the Link 150 M3 MCU is connected to your telephone system via analog lines, refer to the for analog systems. • If your Link 150 M3 MCU is connected to a digital key telephone system or PBX, refer to the document that deals specifically with your brand of telephone system.
  • Page 34: Site Certification

    The SpectraLink field service engineer should not leave the site before contacting SpectraLink to perform remote install verification. Contact a SpectraLink engineer on the Customer Support Hotline at (800) 775-5330. The hours of operation are 6 a.m. to 6 p.m. Mountain time, Monday through Friday.
  • Page 35: System Administration

    Base Station to display its error code. For additional assistance in troubleshooting your system, please contact the SpectraLink Customer Support Hotline at (800) 775-5330. The hotline is open Monday through Friday, 6 a.m. to 6 p.m. Mountain time.
  • Page 36: Status Led Codes

    SpectraLink Corporation Status LED Codes STATUS LEDs Description 1 2 3 4 5 Random The Link 150 M3 MCU is powering up. Cycling Initialization to follow. Link 150 M3 MCU is initalizing. 1, 2, 3, or 4 MCU identification number.
  • Page 37 Turn off the MCU, place the mode switch in the NORMAL position and turn back on.. Check to see if the system was powered on with the switch in the wrong position. If not, contact SpectraLink Customer Service. Turn off the MCU, place the mode switch in the NORMAL position and turn back on.
  • Page 38 If the problem persists, contact technical support. This message should disappear when the telephone system ports are wired and programmed correctly. Register the handset. Installation and Operation Link WTS – Link 150 M3 MCU Action Page 38...
  • Page 39: Replace A Handset

    PN: 72-0075-01-F.doc position on the MCU. REGISTER button. position. REGISTER position. NORMAL key until displays on the handset. Press EXTENSION Installation and Operation Link WTS – Link 150 M3 MCU NORMAL key until Volume Level , then Page 39...
  • Page 40: Replace An Mcu

    NORMAL ), shown on the LEDs. If this is not the case, STATUS STATUS Installation and Operation Link WTS – Link 150 M3 MCU position. ADMIN , and of the replacement ports lit, the configuration data has Page 40...
  • Page 41: Replace A Base Station

    • If the LED turns solid red, there should be an error message on the MCU’s LEDs and the MCU STATUS PN: 72-0075-01-F.doc LED should be lit. ERROR Installation and Operation Link WTS – Link 150 M3 MCU Page 41...
  • Page 42: 10. Link Wireless Telephone Planning Worksheet

    MCU ID: _________ Handset # Extension 2 ** *On MCU No. 1: Reserve Port 1 for access to SpectraLink Diagnostic Modem **On MCU No. 1: Port 2 is used for administrative programming (analog system only) PN: 72-0075-01-F.doc...
  • Page 43: 11. Base Station Location Worksheet

    Base Station # (e.g.: building, floor #, detailed description) Base Station 1 Base Station 2 Base Station 3 Base Station 4 PN: 72-0075-01-F.doc Link WTS – Link 150 M3 MCU Location Location Location Location Installation and Operation Port ID Port ID...
  • Page 44: Select Alternate Spread Spectrum Sequence

    LEDs should be lit, indicating frequency STATUS LEDs from will be indicating the current LINE button. The LED indicates the new frequency that has been position. NORMAL Installation and Operation Link WTS – Link 150 M3 MCU Page 44...
  • Page 45: Change Companding

    Before you begin, if the system has more than one MCU, erase the configurations from all MCUs except MCU 1. Refer to section 9.5 Replace an MCU for instructions. To change the default from Mu- to A-law on the Link 150 M3 MCU follow these steps. 1. Power the system off.
  • Page 46 Two-wire analog or digital, 20 Diagnostic Modem, 16 Error Codes, 35 ESD bonding strap, 24 Extension numbers, 39 Batteries, 24 PN: 72-0075-01-F.doc Link WTS – Link 150 M3 MCU Index Forms Base Station location, 43 Wireless Telephone Planning Worksheet, 42 Frequency, transmission, 44...
  • Page 47 Spread Spectrum Sequence, 44 STEP Button, 11 Switch type, 26 Ports, 16 Troubleshooting, 35 PN: 72-0075-01-F.doc Installation and Operation Link WTS – Link 150 M3 MCU Unregister Wireless Telephone, 32 Walk test, 34 Wireless Telephone Description, 10 Planning Worksheet, 42 Program, 33...

Table of Contents