SpectraLink SCA408 Installation Manual

Spectralink sca408: install guide
Hide thumbs Also See for SCA408:

Advertisement

Link 150 M3 MCU
Open Applications Interface (OAI) Gateway

Installation and Setup

Link Wireless Telephone System
Part Number: 72-0075-07
Issue D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCA408 and is the answer not in the manual?

Questions and answers

Summary of Contents for SpectraLink SCA408

  • Page 1: Installation And Setup

    Link 150 M3 MCU Open Applications Interface (OAI) Gateway Installation and Setup Link Wireless Telephone System Part Number: 72-0075-07 Issue D...
  • Page 2: Trademark Information

    No representation or other affirmation of fact contained in this document including but not limited to statements regarding capacity, response-time performance, suitability for use, or performance of products described herein shall be deemed to be a warranty by SpectraLink for any purpose, or give rise to any liability of SpectraLink whatsoever.
  • Page 3: Important Safety Information

    SpectraLink Corporation WARNING: Changes or modifications to this equipment not approved by SpectraLink Corporation may cause this equipment to not comply with part 15 of the FCC rules and void the user’s authority to operate this equipment. WARNING: SpectraLink products contain no user-serviceable parts inside. Refer servicing to qualified service personnel.
  • Page 4: Table Of Contents

    SpectraLink Corporation 1. About This Document SpectraLink Corporation Model Numbers Related Documents Customer Support Hotline Icons and Conventions 2. Installation Overview 3. OAI Overview System Diagram The OAI Gateway’s Front Panel 4. Installing the OAI Gateway Mount OAI Gateway to Wall...
  • Page 5: About This Document

    Available at http://www.spectralink.com/consumer/resources/interface_guides.jsp. Customer Support Hotline SpectraLink wants you to have a successful installation. If you have questions please contact our Customer Support Hotline at (800) 775-5330. The hotline is open Monday through Friday, 6 a.m. to 6 p.m. Mountain time.
  • Page 6: Installation Overview

    It is important to coordinate the activities among the persons involved. 1. Site Preparation one by the customer or a wire technician/contractor. 2. OAI Gateway Installation: Done by the customer or SpectraLink. 3. System Certification: Done after installation to confirm the system is working properly.
  • Page 7: Oai Overview

    SpectraLink Corporation OAI Overview The OAI Gateway (MOG 500) allows the Link 150 M3 MCU to interface with an application server as shown in the diagram below. This enables third-party applications to communicate directly with the Link 150 M3 MCU, allowing users to retrieve and respond to information using Link Wireless Telephones, or handsets.
  • Page 8: The Oai Gateway's Front Panel

    SpectraLink Corporation The OAI Gateway’s Front Panel The OAI Gateway’s front panel has the following status indicators. • : Indicates an internal error ERROR • LEDS: STATUS LED 1: Future use LED 2: Future use LED 3/IPC: Indicates the status of the communication between the OAI Gateway and the other MCUs.
  • Page 9: Installing The Oai Gateway

    If the LED comes on at any time, there is a hardware problem. Note ERROR which other LEDs are on (if any) and contact SpectraLink Customer Service. PN: 72-0075-07-D.doc Open Application Interface Gateway Installation and Setup Link WTS – Link 150 M3 MCU...
  • Page 10: Connect The Oai Gateway To The Mcu

    Open Application Interface Gateway Installation and Setup port on the MCU, using the IPC cable ports are correctly connected on all MCUs. port; the last MCU is connected LED is on, contact SpectraLink ERROR LEDs of each MCU. If this does not STATUS...
  • Page 11: Connect The Oai Gateway To The Application Server

    SpectraLink Corporation Connect the OAI Gateway to the Application Server Using a standard 9-pin female D-type connector, connect the serial port on the front panel of the OAI Gateway to the PC, application server, or modem that will be used to interface with the application.
  • Page 12: Assign Oai Function Key

    SpectraLink Corporation Assign OAI Function Key To access the OAI application, the user presses Follow these steps to assign a function key to initiate the OAI application. 1. Make sure a handset is registered to administration access. 2. With the system up and running and within range of a Base Station, move the mode switch on the MCU to the 3.
  • Page 13: Certification Test

    SpectraLink Corporation Certification Test When the OAI Gateway is properly connected to the application server, the LEDs should look like this: ERROR LED 1 LED 2 LED3/IPC LED4/SD LED5/RD To test the handsets: • If this is a new installation, continue with handset registration and PBX programming, and perform the usual voice and coverage tests when handset installation is complete.
  • Page 14: Troubleshooting

    SpectraLink Corporation Troubleshooting When an alarm is detected, the LEDs will display an alarm code. Contact SpectraLink Customer Support at (800) 775-5330 (Monday through Friday, 6 a.m. to 6 p.m. Mountain time) for additional assistance in troubleshooting your system. The following...