Installation; Overview - Cooper 9930 User Manual

Hardwired control unit
Table of Contents

Advertisement

Caution: Always remove mains power before opening the case lid. Do
not work inside the control unit with mains power present.

Overview

A typical installation comprises the following main steps:
1.
Survey the site and decide on positions for wired detectors, control unit,
keypads, external and internal sounders. As part of the survey ask the
users what facilities they need.
2.
Ensure that there is a suitable mains supply present at the site of the
control unit.
3.
If you are going to use a communicator, arrange for a PTT (Public
Telephone and Telegraph) connection point near to the control unit.
4.
Install the wired detectors and run cables to the site of the control unit.
Connect each detector to its cable.
5.
Run cables from the sites of the keypads, external and internal sounders
to the site of the control unit.
6.
Install keypads and connect them to their cabling. Ensure that each one
has the correct address setting. If necessary, install 934 ScanProx
modules on the keypads.
7.
Install internal and external sounders and connect them to their cabling.
8.
Install the control unit and connect it to the mains supply cabling. Do not
apply power at this point.
9.
At the control unit, complete all connections to detectors, keypads and
sounders.
10. Apply power and program the control unit.
11. Test that the intruder alarm system operates as required.
12. If required, install a communicator, connect it to the PTT network and
check that it operates correctly.
13. Hand the system over to the users and instruct them in its use.