Operating Instructions Webmodule ZB-S 1 Safety permitted. 3.1 Description / Scope of application Instructions 4.2 Electrical connection The webmodule ZB-S for The Webmodule ZB-S shall visualisation and monitoring only be used for its intended of a central battery system purpose and in undamaged ZB-S via local ethernet (LAN) and perfect condition!
Operating Instructions Webmodule ZB-S Connection of the data cable to the control unit ST-S Note: Keep the distance of the data cable between the webmodule and the con- trol unit ST-S as short as possible. Please avoid a wiring around the char- ging unit.
Operating Instructions Webmodule ZB-S Furthermore the webbrow- During activities on the con- ser shows „data is synchro- trol unit of the ZB-S, e.g. nized“. The connection will programming of luminaires, automatically be restored it is possible that the con- after a short time. nection between the control unit and the webmodule is 4.5 Monitoring via an...
Operating Instructions Webmodule ZB-S Homepage / Login By entering the TCP/IP- Ex works 2 logins are given address (s. 5.a: ex works: which can be modified 192.168.1.200) in the individual at anytime: internet-browser the home- page will open. CEAG Notlichtsysteme GmbH...
Page 7
Operating Instructions Webmodule ZB-S 5.1: User: Admin 5.2: User: Guest Password: ceag Note: Password:(no password required) Change the factory set Permits unlimited use of the password to avoid an web server. unauthorized access! Permits only access to status information. 5.1+5.2 5.3: A change of the password for the acutal ac-...
Operating Instructions Webmodule ZB-S Submenus coloured: 6.1.3 Choosing the me- 6.1 Overview ZB-S green: function o.k. nus on the left side you get 6.1.1 After successful yellow: FT/BT runs in the marked submenus. login the mask „Overview red: function failure ZB-S“...
Operating Instructions Webmodule ZB-S 6.2 Overview SKU 6.2.1 In the mask „over- 6.2.2 With a click on the view SKU“ the informati- individual circuit the appen- on about the equipment dant mask starts. of the subracks with the corresponding SKU´s is displayed with the following statuses: green: circuit o.k.
Page 10
Operating Instructions Webmodule ZB-S 6.2.3 Circuit mask The status of the luminaire 6.2.3.1 The circuit mask is shown as follows: shows the status of circuit grey: offline as well as yellow: online red: failure 6.2.3.2 the installed luminaires with marking of destination and switch allocation.
Operating Instructions Webmodule ZB-S 6.3 DLS/TLS/3PhW yellow: input active In the following mask all grey: input not active installed DLS-modules, red: phase failed TLS-modules, DLS/3PhW- modules are shown with the information on destination, status of module and input: CEAG Notlichtsysteme GmbH...
Operating Instructions Webmodule ZB-S 6.4 Settings 6.4.2 „Website setup“: - choosing language In the mask „Settings“ the - Update interval of the main parameters of the website (standard on 30 webserver can be installed: sec.) 6.4.1 „User administra- 6.4.3 „Network setup“: tion“: Input of new user Please contact the IT- with different authorities.
Page 13
Operating Instructions Webmodule ZB-S 6.4.4 „E-mail Options“: The CEAG ZB-S webmo- dule has an integrated mail-client, which can send an Email to up to 5 email- addressees in case of an adjustable event (s.chap- ter. 6.5: „Email-messages). You get the necessary infor- mation from your relevant IT-department (e.g.
Operating Instructions Webmodule ZB-S 6.5 Email-Messages In this menu it can be cho- sen in which case of failure an Email shall be send. CEAG Notlichtsysteme GmbH...
Operating Instructions Webmodule ZB-S 6.6 Other webmodules This menu shows all in- statuses (exact function stalled ZB-S webmodules has to be permitted by the IT-department) in the network including their addresses and acutal Choose webserver by clik- king on its name, than the relevant mask will appear.
Operating Instructions Webmodule ZB-S Example of loca- „Failure“ and „Lu- minaire failure“ are red. ting a luminaire failure By clicking on „Status SKU´s“ the relevant When locating a failure after circuit will open. a function test the following statuses are shown on the mask „Overview ZB-S“: CEAG Notlichtsysteme GmbH...
Page 17
Operating Instructions Webmodule ZB-S Example of loca- ting a luminaire failure When clicking In the most „Status SKU´s“ on the relevant circuit the the failed circuits are shown attended mask appears. in a red colour. CEAG Notlichtsysteme GmbH...
Page 18
Operating Instructions Webmodule ZB-S Example of loca- location of the luminaire. ting a luminaire After repairing the luminaire failure a further function test has to be done for reset the The failed luminaires are display. shown red coloured under the point „state“. For an easier orientation name the CEAG Notlichtsysteme GmbH...
Operating Instructions Webmodule ZB-S Data gets synchro- nized Changing the configuration on the ZB-S control unit (e.g. with CGVision) the following mask could be shown: It is shown that changes of configuration on the control Note: If necessary unit get synchronized with an update of this display in the webserver.
Page 20
In case of returns you need a RMA-number from us. For further information see www.ceag.de! - We reserve the right to carry out technical changes! - CEAG Notlichtsysteme GmbH Senator - Schwartz - Ring 26 D-59494 Soest Phone +49 29 21/69-870 +49 29 21/69-617 Internet http://www.ceag.de...
Need help?
Do you have a question about the CEAG Webmodule ZB-S and is the answer not in the manual?
Questions and answers