Control Unit Specification

General

Environmental
Security
Operating temperature
Humidity
Dimensions
Weight
Internal Clock
Suitable for use in a system that is designed to comply with EN50131-1,
ACPO-IAS Policy, NSI NACP14.

Power Supply

All currents accurate to ±5%.
Mains power supply
System power supply
Battery charge current limit
To comply with the requirements of EN50131, the total current taken from the
power supply, not including the battery recharge current, but including
auxiliary outputs and other devices, must not exceed 750mA.
Nominal power requirements (DC):
Standby battery (not supplied) 12V rechargeable lead-acid, gel-type battery.
Note: Grade 1 and 2 compliance requires the panel to continue for a minimum
period of 12 hours on a standby battery. To calculate the minimum
capacity battery to achieve this requirement, determine the total current
taken by external devices and the panel and multiply by 12.
Note that a 17Ah battery cannot fit inside the case.

2. TECHNICAL DESCRIPTION

497283 Issue 1
Class 2
EN50131-1 or PD6662 Grade 2
-10° to +55°C
96% RH
235mm W, 245mm H, 90mm D
3.3 kg
±10 minutes over one year (depending on the
accuracy of the mains supply frequency).
230VAC +10%/-15%, 200mA max, 50Hz ±5%
13.8VDC, 1.0A
250mA
9651
130mA quiescent, 220mA active
9930
20mA quiescent, 35mA backlight on
9940
30mA quiescent, 70mA backlight on
934
15mA typical, 20mA maximum
Low battery voltage cutoff = 10V.
Recommended manufacturers: Yuassa, Yucel
or Fiamm.