Prior to Installation

Care must be taken to ensure the safety of those installing this
equipment. Always verify that the method of installation will be suitable
for the environmental and operating conditions in which this system will
need to perform.
To prevent injury, death, or damage to your photovoltaic system, use
caution when handling this equipment. Much of this equipment is heavy
and should be handled by two people. Never install this equipment
when weather conditions may pose a risk of danger. Always use
insulated tools and never wear jewelry or other metallic clothing, as
these modules may generate electricity whenever light is present.
Always cover the solar array's front surface with an opaque material to
reduce the risk of electrical generation during installation and when
performing maintenance operations. Do not install wiring when fingers
Components
This solar energy system is comprised of system components. Not
included is the SCH40 pole needed for mounting this equipment or any
other associated supplies (concrete, grounding rod, U-bolts, etc.).
Catalog Number
SOL 5W 12V 7 WR 3R
SOL 20W 12V 36 WR 3R
SOL 20W 12V 48 WR 3R
SOL 30W 12V 36 WR 3R
SOL 30W 12V 48 WR 3R
SOL 30W 12V 70 WR 3R
SOL 40W 12V 36 WR 3R
SOL 40W 12V 48 WR 3R
SOL 40W 12V 70 WR 3R
SOL 50W 12V 48 WR 3R
SOL 50W 12V 70 WR 3R
SOL 65W 12V 48 WR 3R
SOL 75W 12V 70 WR 3R
SOL 80W 12V 99 WR 3R
SOL 5W 12V 7 WR 3R 2
SOL 20W 12V 36 WR 3R 2
SOL 20W 12V 48 WR 3R 2
SOL 30W 12V 36 WR 3R 2
SOL 30W 12V 48 WR 3R 2
SOL 30W 12V 70 WR 3R 2
SOL 40W 12V 36 WR 3R 2
SOL 40W 12V 48 WR 3R 2
SOL 40W 12V 70 WR 3R 2
SOL 50W 12V 48 WR 3R 2
SOL 50W 12V 70 WR 3R 2
SOL 65W 12V 48 WR 3R 2
SOL 75W 12V 70 WR 3R 2
SOL 80W 12V 99 WR 3R 2
IF 1589 • 08/09
CAUTION
are wet.
Panel
Battery
5 Watt
12 VDC, 7 Ahr
20 Watt
12 VDC, 36 Ahr
20 Watt
12 VDC, 48 Ahr
30 Watt
12 VDC, 36 Ahr
30 Watt
12 VDC, 48 Ahr
30 Watt
12 VDC, 70 Ahr
40 Watt
12 VDC, 36 Ahr
40 Watt
12 VDC, 48 Ahr
40 Watt
12 VDC, 70 Ahr
50 Watt
12 VDC, 48 Ahr
50 Watt
12 VDC, 70 Ahr
65 Watt
12 VDC, 48 Ahr
75 Watt
12 VDC, 70 Ahr
80 Watt
12 VDC, 99 Ahr
5 Watt
12 VDC, 7 Ahr
20 Watt
12 VDC, 36 Ahr
20 Watt
12 VDC, 48 Ahr
30 Watt
12 VDC, 36 Ahr
30 Watt
12 VDC, 48 Ahr
30 Watt
12 VDC, 70 Ahr
40 Watt
12 VDC, 36 Ahr
40 Watt
12 VDC, 48 Ahr
40 Watt
12 VDC, 70 Ahr
50 Watt
12 VDC, 48 Ahr
50 Watt
12 VDC, 70 Ahr
65 Watt
12 VDC, 48 Ahr
75 Watt
12 VDC, 70 Ahr
80 Watt
12 VDC, 99 Ahr
Copyright © 2009, Cooper Industries, Inc.
During Installation and Maintenance
Under no circumstance should this system be installed or operated
with a damaged solar panel backsheet. Extra care should be taken
not to damage the backsheet by dropping it or hitting it with an
object. Always mount the solar modules so that the junction box is located
at the upper edge of the module. These should also be installed at an
angle of no less than 10 degrees (10º) from the horizontal for ease of
regularly scheduled cleaning and to help in self-cleaning. Make certain
that all electrical connections are securely connected and are done so in a
manner to reduce the chance of unauthorized personnel tampering
(purposely or inadvertently) with the apparatus. Never attach anything to
the back of the module, and make certain to allow for adequate ventilation
to the back of the module to reduce the risk of heat build-up.
Note
Other catalog numbers are available upon request.
Regulator
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Enclosure
Circuit Protectors
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Ordinary Location
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
16" x 16" x 10"
Class I, Division 2
Page 2