Safety Instructions; Conformity With Standards; Technical Data; Description / Scope Of Application - Cooper CEAG Webmodule ZB-S Operating Instructions Manual

Webmodule
Table of Contents

Advertisement

1 Safety
Instructions
The Webmodule ZB-S shall
only be used for its intended
purpose and in undamaged
and perfect condition!
When working on the elec-
tronic device make sure that
it is disconnected from the
voltage! Pay attention to the
different power supplies in
mains or battery operation.
Observe the national safety
rules and regulations for
prevention of accidents as
well as the safety instruc-
tions included in these ope-
rating instructions marked
with
!
2
Conformity with
standards
Conform to: EN 60950-1.
Developed, manufactu-
red and tested acc. to ISO
9001.
3

Technical data

Supply
voltage:
24 V DC
Power
consumption:
< 1.5 W
Connection: RJ45
Insulation class: III
Degree of protection acc. to
EN 60529:
IP 20
Ambient temperature:
-10 °C .. +55 °C
Connection
terminal:
1,5 mm²
Weight: 0,1kg
Dimensions:
90 x 35 x 58mm
Operating Instructions
Webmodule ZB-S
3.1 Description /
Scope of application
The webmodule ZB-S for
visualisation and monitoring
of a central battery system
ZB-S via local ethernet (LAN)
with a customary WEB-brow-
ser (e. g. Internet Explorer
Integrated mail-client for a
comfortable and event based
failure notification for up to 5
email addressees. Password
protected access accounts
capable of parametrisation.
Note:
For operation of the web-
module with a ZB-S system
the following software-state
must be installed in the con-
trole module:
P/F/H (Mega 128/RS485/
FTT 10A)
4

Installation

For the mounting
and operation of
electrical apparatus, the
respective national safety
regulations as well as the
general rules of engineering
will have to be observed!

4.1 Mounting

Pay attention to tempera-
tures outside the permitted
range during operation. The
permissible ambient tem-
perature may not exceed
55°C.
The module was designed for
DIN rail mounting (2TE) to be
only mounted in the cabinet.
An external mounting out-
side the ZB-S cabinet is not
permitted.

4.2 Electrical connection

).
TM
Störung
Failure
Service
24V
+ -
PE
+ -
PE
24 V DC from
DC/DC inverter
The webmodule ZB-S is
supplied with 24V DC of the
DC-DC inverter of the ZB-S.
The PE connector must be
connected to the protection
earth (PE) in the ZB-S.
Note: The DC-DC inverter
can supply max. 20 pcs.
further DLS/3Ph-busmodu-
les/TLS-modules!
The 6-pole data cable con-
nects the webmodule with
the ST-S control unit:
CEAG Notlichtsysteme GmbH
Status/
Failure LED
Network
connection
RJ45
Service
Pin
Connection of
the 6-pole
data cable to
the control
unit ST-S
3