Note: The log is protected and cannot be erased by the Installer or a user.

91 to 96: Testing Outputs

You may test parts of the system by entering commands at the keypad. To
carry out a test make sure the system is in installer mode and then key in one
of the following commands:
91y Test normal outputs:
Press keys 1 to 3 to toggle outputs 1 to 3 on and off.
92y Test plug-by outputs:
Press keys 1 to 8 to toggle outputs 1 to 8 on and off.
93y Not used.
94y Test the internal sounder output.
95y Test the keypad sounder.
96y Not used.
Press y to end each test. All outputs revert to their former settings.

97: Engineer Walk Test

This function enables the engineer to test all devices on the system.
1.
Enter installer mode.
2.
Press 97y
The display shows:
3.
Open and close each alarm and tamper contact in turn.
The system gives a Chime tone each time you open and close a detector
contact. The display shows: "A: Zone" and the zone number of every
detector you have tested, in sequence and for one second each. If you
also test the tampers on each zone, the display shows the letter "T"
against each zone number.
4.
Press X to stop the Walk Test.
Note: The engineer Walk Test enables you to test all zones, including PA
zones, zone tampers, and control unit and bell tampers. The user Walk
Test does not enable you to test tampers or PA, Fire, 24-hour and
Technical zones.
Meaning
Zone of type 'Fault' active
Power output fault reset in zone ==
Power output fault in zone ==
497283 Issue 1
Programming - Testing Commands
97: Walk Test
Page 75