My appliance isn't working correctly
Error codes
o The burners will be shut down when the hob has tried three
consecutive times to ignite the burner without success.
Solution: Execute the following key sequence for release:
o The burner can be released by pressing the relevant minus
button and the safety lock button (2) simultaneously for at least
two seconds.
o When released, the burner will be restored to level 0 and is
ready to be reignited.
For suggestions regarding why a burner may fail to ignite please see
the table below:
Reason
There is no gas.
Incorrect connection to the
earthing system.
The electrode does not find
the connection.
o The electronic circuit detects the presence of an abnormal or
parasite flame.
o The electronics detect the presence of the flame before having
opened the gas valve and enters a "parasite flame" state and a
flashing "F" appears on the display. If this situation continues for
more than ten seconds, the burner will shut down.
o Another condition for the parasite flame can be a failed valve
seal. This is the condition of wanting to ignite burner A but there
is a leak in burner B so both burners will be ignited.
o Detecting the presence of a parasite flame for more than ten
seconds in a burner for which ignition is not requested, the
electronics will create a general shutdown state.
Solution: Contact the Baumatic Ltd customer care helpline.
Solution
Check that the tap is open.
Check the connections.
Check that the burner cover is
positioned properly in its seat.
31