Electrical Information
WARNING: To avoid electrical hazards, fire hazards, or damage to the tool, use proper circuit protection.
The Snow Thrower is wired at the factory for 120 V operation. Connect to a 120 V, 15 A circuit and use a
15 A time delayed fuse or circuit breaker. To avoid shock or fire when the power cord is worn, cut, or
damaged in any way, replace it immediately.
This Snow Thrower has a 3-prong plug that is intended for use on a circuit
that has a receptacle like the one illustrated in Fig. A.
Do not modify the power cord plug. If it does not match the electrical outlet,
have the proper outlet installed by a qualified electrician.
WARNING: To avoid injury, when servicing the Snow Thrower,
use only identical replacement parts.
Grounding Instructions
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least resistance for
electrical current and reduces the risk of electric shock. This tool is equipped with an electric cord that has a
POLARIZED plug. The plug MUST be plugged into a matching outlet that is properly installed and grounded in
accordance with ALL local codes and ordinances.
DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the outlet, have the proper outlet installed by a qualified
electrician.
Extension Cord
WARNING: In order to reduce the risk of electric shock when operating this Snow Thrower, use only a
CSA-listed extension cord that is approved for outdoor use, such as Type SJTW, 16AWG, and that has
a lower temperature rating of -40° F (-40° C).
• Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit(s) or outlet(s) that will be
used for this Snow Thrower. For an extra measure of safety, use a receptacle that has built-in GFCI protection.
• The nameplate on the Snow Thrower indicates the voltage used. Do not connect the Snow Thrower to an AC
circuit that provides a different voltage from the voltage that is indicated on the nameplate.
Amperage rating of the tool
(120 V circuit only)
More than
0
[Use the same format for the table as found in the file entitled "Recommended size of extension cords".]
WARNING: In order to prevent electric shock, use an extension cord that is suitable for outdoor use.
• Inspect the extension cord and the power cord on a regular basis. Look for deterioration, cuts, or cracks in the
insulation. Inspect the connections for damage. Repair or replace the extension cord or the power cord if any
damage is found.
• Verify that the rotor and all moving parts have come to a complete stop, and disconnect the Snow Thrower from
the power supply in order to prevent accidental start-ups before cleaning or performing any inspections or repairs.
• Do not abuse the extension cord. Do not carry the Snow Thrower by the power cord or pull on the cord in order
to disconnect it from the receptacle.
• Keep the extension cord away from heat, oil, and sharp edges in order to prevent damage.
• If the extension cord is damaged in any manner while it is plugged in, disconnect it from the outlet immediately.
• Avoid accidental start-ups. Do not carry the Snow Thrower with a finger on the switch while it is plugged in.
Verify that the switch is in the "OFF" position before plugging in the Snow Thrower.
• Unplug the Snow Thrower and allow it to cool down before putting it into storage. Store the Snow Thrower indoors.
• Unplug the Snow Thrower when it is not in use and before performing any maintenance or repairs.
GENERAL SAFETY RULES
Recommended size of extension cords
Not more than
12
SAVE THESE SAFETY RULES
Total length of the extension cord
25'
50'
(7.6 m)
(15.2 m)
Minimum Gauge for the extension cord (AWG)
16
16
4
Fig. A
1) 3-prong plug
2) Receptacle with grounding conductor
100'
150'
(30.4 m)
(45.7 m)
14
14
1
2