INSTALLATION – VENTED TO THE OUTSIDE
4
INSTALL DUCT BRACKET
VENTING TO THE REAR (HORIZONTAL EXHAUST)
OR STRAIGHT UP TOP (VERTICAL EXHAUST)
• Temporarily install the 2 small screws into the sides
of the duct bracket. Remove the screws. This will
ensure ease of final installation.
• Position the upper duct bracket against the wall and
ceiling, aligned with CL pencil mark and CL on the
bracket.
• Mark the 4 screw locations of the bracket.
• Remove the bracket.
• Drill 1/8" pilot holes in marked bracket location.
• If pilot holes do not enter studs, enlarge the holes 3/8"
and install wall-fastener anchors. Drive screws into the
fasteners to allow anchors to expand against the wall
material. Remove the screws.
• Secure the bracket to the ceiling and wall with wood
screws and/or wall-fastener screws.