Installation
Instructions
INSTALLATION-VENTED T OTHEOUTSIDE
[_
INSTALL MOUNTING
BRACKET
This vent hood must be secured to the horizontal
support
or wall studs.
• With the template
taped in place, use a punch to
mark mounting
bracket screw locations.
• Drill 3/!6"
pilot holes in 2 of the punched locations
in the lower bracket.
• Remove the template.
REAR WALL
MOUNTING TEUPLATE
* Use wood screws to secure the mounting
bracket
to the wall. The screws must engage wall studs or
the installed horizontal
mounting
support.
* Check to be sure that the bracket is level.
_1
INSTALL DUCT BRACKET
The duct bracket should be installed against the
back wall and flush with the ceiling. This bracket will
hold the duct cover in place at the top.
Secure the bracket
to the wall:
., Align the marked centerline on the bracket with
the centerline
on the wall.
• Mark 2 screw hole locations
in the wall.
• Drill 3/!6"
pilot holes in the marked locations.
• If pilot holes do not enter studs, enlarge the holes
to 3/8" and install wall fastener
anchors.
• Drive screws, bg hand, into the fasteners to allow
anchors to expand. Remove the screws.
• Secure the bracket to the wall with wood screws
and/or fasteners.
\
/
/