Connectors; Analog Audio Input; Analog Audio Output - Orban OPTIMOD 6300 Operating Manual

Digital multipurpose audio processor, version 1.1 software
Hide thumbs Also See for OPTIMOD 6300:
Table of Contents

Advertisement

2-6
INSTALLATION

Connectors

Analog Audio Input

Analog Audio Output

Input and output connectors are XLR-type connectors.
In the XLR-type connectors, pin 1 is CHASSIS GROUND, while pin 2 and
pin 3 are a balanced, floating pair. This wiring scheme is compatible with
any studio-wiring standard: If pin 2 or 3 is considered LOW, the other pin
is automatically HIGH.
Nominal input level between –14dBu and +8dBu will result in normal operation
of the 6300.
(0dBu = 0.775Vrms. For this application, the dBm @600 scale on voltme-
ters can be read as if it were calibrated in dBu.)
The peak input level that causes overload is +27.0dBu.
The electronically balanced input uses an ultra low noise and distortion differen-
tial amplifier for best common mode rejection and is compatible with most pro-
fessional and semi-professional audio equipment, balanced or unbalanced, hav-
ing a source impedance of 600 or less. The input is EMI suppressed.
Input connections are the same whether the driving source is balanced or unbal-
anced.
Connect the red (or white) wire to the pin on the XLR-type connector (#2 or #3)
that is considered H
wire to the pin on the XLR-type connector (#3 or #2) that is considered L
the standards of your organization.
In low RF fields (like a studio site not co-located with an RF transmitter), connect
the cable shield at 6300 input only—it should not be connected at the source
end. In high RF fields (like a transmitter site), also connect the shield to pin 1 of
the male XLR-type connector at the 6300 input.
If the output of the driving unit is unbalanced and does not have separate
and (–) (or L
C
G
HASSIS
ROUND
the black wire to the common (–) or ground terminal of the driving unit.
Electronically balanced and floating outputs simulate a true transformer output.
The source impedance is 50. The output is capable of driving loads of 600 or
higher; the 100% modulation level is adjustable with the AO 100% control over
a –6dBu to +24dBu range. The outputs are EMI suppressed.
by the standards of your organization. Connect the black
IGH
) output terminals, connect both the shield and
OW
ORBAN MODEL 6300
by
OW

Advertisement