Configuring Alarm Input / Output Settings - HIKVISION DS-6300DI-T User Manual

Video/audio decoder
Table of Contents

Advertisement

User Manual of DS-6300DI-T Decoder
Click Configuration > Serial Port Settings > RS-485 Port to enter the following interface:
1.
Configure the RS-485 parameters, including the baud rate, data bit, stop bit and parity type.
2.
Click Save to save the settings.
3.

4.2.6 Configuring Alarm Input / Output Settings

Purpose:
As the Decoder is unable to obtain the alarm signal over network, it must be connected with external alarm
input/output.
Steps:
Alarm Input Settings
Click Configuration > Alarm Settings > Alarm Input to enter the alarm setting interface.
1.
Set the Alarm Sensor Type for the selected alarm input and configure the Alarm Input Handling actions.
2.
By default, the Alarm Mode is in NO (Normally Open).
Click Save to save the settings.
3.
Alarm Output Settings
Click Configuration > Alarm Settings > Alarm Output to enter the alarm setting interface.
1.
Select the alarm output, you can also customize the output delay time. Output delay time refers to the
2.
duration of the alarm after the alarm output, for example, when you set the alarm output delay time as 10
seconds, when an alarm occurs the alarming time lasts 10 seconds later than the time of the alarm
stopped.
Figure 4.31 Configure RS-485 Settings
Figure 4.32 Configure Alarm Input Settings