Thermostat Installer Options; Setting The Home Number; Setting The Zone Number - Jackson Systems Wireless Comfort WCT-32 Installation Manual

7-day programmable, battery powered thermostat
Hide thumbs Also See for Wireless Comfort WCT-32:
Table of Contents

Advertisement

7

Thermostat Installer Options

The installer options can be accessed by
pressing and holding the
seconds. The LCD displays Option 01 for setting
the
number. (See Installer Options Chart)
Zone
Press or hold the
NEXT
next option. The LCD will advance through to
Option 16 and then return to Option 01.
Press the
ENTER
key to save all options in non-
volatile flash ram.
If only one wireless thermostat and HVAC Control
Module are used in an application, the thermostat
can be left with the factory default setting of
= 01
and
Home = 01.
If multiple wireless thermostats and HVAC
Control Modules are used that are less than 500
feet away from one another, each thermostat
must be set to a different
convenience, set the Installer Options with the
thermostat off the subbase and in easy access of
its HVAC Control Module.
8

Setting the Zone Number

Use the
Up
and
Down
keys to set the
number for the each thermostat. The
number can be set from 01 to 08.
Option
CANCEL
Zone Numbers can be used to identify individual
thermostats. Press the
NEXT
the next option. Press the
options are to be changed.
ENTER
key for seven
key to advance to the
Zone
Home
number. For
Zone
Zone
Zone
NEXT
ENTER
key to advance to
ENTER
key if no more
Installer Options Chart
Option
Description
01
Zone number
Range
01 to 08
Default
01
02
Home number
Range
01 to 32
Default
01
03
Program HVAC module with Zone
and Home address - Default 01
04
Equipment type
Range
00- G/E 01- Heat Pump
Default
00- G/E
05
Indoor Fan Operation
Range
00- Gas 01- Electric
Default
00- Gas
06
Minimum Off Time
Range
01 to 09 minutes
Default
00 minutes
07
Minimum Run Time
Range
01 to 09 minutes
Default
00 minutes
08
Maximum allowable heating setpoint
Range
60 to 85F
Default
85F
09
Minimum allowable cooling setpoint
Range
55 to 80F
Default
65F
10
Heat/Cool Setpoint Differential
Range
02 to 06F
Default
02F
11
Stage 1 Temperature Differential
Range
01 to 04F
Default
01F
12
Stage 2 Temperature Differential
Range
01 to 10F
Default
03F
13
Stage 3 Temperature Differential
Range
01 to 12F
Default
05F
14
Staging Time
Range
0 = OFF 1 = ON
Default
0
15
Staging Time When 14 = 1 (ON)
Range
15 - 30 (1 Minute Increments)
Default
15
16
Automatic Backup
Range
00- Off 01- On
Default
01- On
9

Setting the Home number

Press the
key to select
NEXT
number is used to distinguish between
Home
thermostats and HVAC Control Modules that are
less than 500 feet away from one another. This
could be a home with two HVAC systems or a
multi-family residence.
4
. T
he
Option 02

Advertisement

Table of Contents
loading

Table of Contents