Thermostat Installer Options; Setting The Zone Number; Setting The Home Number - Jackson Systems WCT-32 Installation Manual

Hide thumbs Also See for WCT-32:
Table of Contents

Advertisement

7

Thermostat Installer Options

The installer options can be accessed by
pressing and holding the ENTER key for seven
seconds. The LCD displays Option 01 for setting
the Zone number. (See Installer Options Chart)
Press or hold the NEXT key to advance to the
next option. The LCD will advance through to
Option 16 and then return to Option 01.
Press the ENTER key to save all options in non-
volatile flash ram.
If only one wireless thermostat and HVAC Control
Module are used in an application, the thermostat
can be left with the factory default setting of Zone
= 01 and Home = 01.
If multiple wireless thermostats and HVAC
Control Modules are used that are less than 500
feet away from one another, each thermostat
must be set to a different Home number. For
convenience, set the Installer Options with the
thermostat off the subbase and in easy access of
its HVAC Control Module.
8

Setting the Zone Number

Use the Up and Down keys to set the Zone
number for the each thermostat. The Zone
number can be set from 01 to 08.
Option
CANCEL
Zone Numbers can be used to identify individual
thermostats. Press the NEXT key to advance to
the next option. Press the ENTER key if no more
options are to be changed.
Zone
NEXT
ENTER
Installer Options Chart
Option
Description
01
Zone number
Range
01 to 08
Default
01
02
Home number
Range
01 to 32
Default
01
03
Program HVAC module with Zone
and Home address - Default 01
04
Equipment type
Range
00- G/E 01- Heat Pump
Default
00- G/E
05
Indoor Fan Operation
Range
00- Gas 01- Electric
Default
00- Gas
06
Minimum Off Time
Range
01 to 09 minutes
Default
00 minutes
07
Minimum Run Time
Range
01 to 09 minutes
Default
00 minutes
08
Maximum allowable heating setpoint
Range
60 to 85F
Default
85F
09
Minimum allowable cooling setpoint
Range
55 to 80F
Default
65F
10
Heat/Cool Setpoint Differential
Range
02 to 06F
Default
02F
11
Stage 1 Temperature Differential
Range
01 to 04F
Default
01F
12
Stage 2 Temperature Differential
Range
01 to 10F
Default
03F
13
Stage 3 Temperature Differential
Range
01 to 12F
Default
05F
14
Staging Time
Range
0 = OFF 1 = ON
Default
0
15
Staging Time When 14 = 1 (ON)
Range
15 - 30 (1 Minute Increments)
Default
15
16
Automatic Backup
Range
00- Off 01- On
Default
01- On
17
Temperature Calibration
Range
40 - 95
Default
Factory Calibrated
9

Setting the Home number

Press the NEXT key to select Option 02. The
Home number is used to distinguish between
thermostats and HVAC Control Modules that are
less than 500 feet away from one another. This
could be a home with two HVAC systems or a
multi-family residence.
4

Advertisement

Table of Contents
loading

Table of Contents