4.2 - CONFIGURATION

4.2.1 - General

Four types of configuration are available:
w The factory configuration. It describes the "hardware" structure of the unit (e.g. the number of compressors,
w The Service configuration. It allows to modify operating parameters. This configuration is accessible
w The User configuration. It allows to modify a limited number of simple parameters (i.e. loading sequence,
w The network configuration. It allows to modify parameters used by network functions (i.e. Alarm POC,
4.2.2 -Main interface configuration sub menu tree structure
MAIN INTERFACE FACTORY CONFIGURATION SUB MENU TREE STRUCTURE
Downloaded from
www.Manualslib.com
CARRIER SA
30GX&HX PRO_DIALOG 4 V.2
valve...). This configuration is accessible through the Main Interface Factory menu Menus or the Network
Service Tool and can be done by Carrier factory or service only.
through the Main Interface Service Menus or the Network Service Tool and can be done by Carrier
factory or service only.
start-up delay, cooler pumps control, reset select...). This configuration can be done through the Main
Interface or through the Network Service Tool. This configuration can be modified by the customer.
Broadcast ...). This is accessible through the Building Supervisor or the Network Service Tool.
0
''USEr MEnu''
1
''USEr 1''
''USEr 2''
2
I
3
''dAtE''
T
4
''SCHEduLE 1''
E
5
''SCHEduLE 2''
M
''HoLidAY''
6
S
7
'broAdCASt''
0
"FACtorY1 MEnu"
1
2
nb fan a (idem version 1.x)
I
3
nb fan b (idem version 1.x)
T
hd selec (idem version 1.x)
4
E
5
econ sel (idem version 1.x)
M
6
S
7
cpa1_mta (idem version 1.x)
cpa2 mta (idem version 1.x)
8
9
cpb1 mta (idem version 1.x)
10
cpb2 mta (idem version 1.x)
hr temp (idem version 1.x)
11
12
recl_opt (idem version 1.x)
13
evap_pas (idem version 1.x)
14
15
heat sel (idem version 1.x)
16
17
pd4_aux (aux board select)
18
19
TQ_r_fbk (TQ valve feeddback)
NOT TO BE DISCLOSED TO PERSONS OUTSIDE CARRIER ORGANIZATION
manuals search engine
USER'S GUIDE FOR
CONFIGURATION SUB MENUS
USER
SERVICE
''SErViCE MEnu''
''SErViCE 1''
''SErViCE 2''
''SErViCE 3''
''MAStEr SLAvE''
FACTORY CONFIGURATION SUB-SUB MENUS
FACTORY 1
"FACtorY2 MEnu"
unit_typ (idem version 1.x)
oil_sel (idem version 1.x)
cira lwt (idem version 1.x)
exva max (1500)
exvb max (1500)
C
©
.
ARRIER S
A
ECG - UG - 02 - 02
Page: 20 /98
Rev: Original
FACTORY
"FACtorY MEnu"
"FACtorY 1 MEnu"
"FACtorY 2 MEnu"
FACTORY 2
fac_pass