Industrial 2 of 5
Status (Industrial 2 of 5)
Usage:
Used primarily in warehouse sortation, photo finishing, and the sequential
numbering of airline tickets.
Definition:
Microscan recommends that Industrial 2 of 5 always be used with fixed
symbol length settings in any application. Symbol Length # 1 and Symbol
Length # 2 can both be set to 0 to allow the reader to decode Industrial 2 of
5 symbols of varying lengths.
Serial Cmd:
<K488,status,check character status,check character output status,format,
symbol length #1,symbol length #2>
Default:
Disabled
Options:
0 = Disabled
Check Character Status (Industrial 2 of 5)
Definition:
When this field is enabled, a check character is added.
Serial Cmd:
<K488,status,check character
symbol length #1,symbol length #2>
Default:
Disabled
Options:
0 = Disabled
Check Character Output Status (Industrial 2 of 5)
Definition:
When this field is enabled, the check character will be output with symbol
data. When disabled, the check character will not be output with symbol
data.
Serial Cmd:
<K488,status,check character
symbol length #1,symbol length #2>
Default:
Disabled
Options:
0 = Disabled
Format (Industrial 2 of 5)
DefinitionL
Defines the number of start and stop check characters.
Serial Cmd:
<K488,status,check character status,check character output status,format,
symbol length #1,symbol length #2>
Default
3 start / 3 stop
Options:
0 = 3 start / 3 stop
MS-2 CCD Reader User's Manual
1 = Enabled
status,check character output status,format,
1 = Enabled
status,check character output
1 = Enabled
1 = 2 start / 2 stop
Symbologies
status,format,
5-15
Need help?
Do you have a question about the MS-2 and is the answer not in the manual?
Questions and answers