Reply Code; Cc-Link Local/Remote Operation - Toshiba TOSVERT VF-AS1 Instruction Manual

Manual for cc-link option - ccl001z
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

6.5. Reply Code

Reply code
Data
0000H
0001H
0002H
0003H

7. CC-Link local/Remote Operation

The example below shows how to configure the VF-AS1 for local/remote operation.
F terminal ................ Operating command
R terminal................ CC-Link local/remote (Terminal in this example) switching
RR/S4 terminal ..... Operation frequency command
<Wiring>
Variable resistor for adjustment
<Parameter setting>
cmod
fmod
f112
<Operation>
R-CC terminal open: VF-AS1 is controlled as a slave device of CC-Link.
R-CC terminal closed:
Item
Normal (No error)
Write error
Parameter selection error
Setting range error
10k ohm
Operation command
CC-Link/local Switch
(Command mode selection) = 0 (Terminal board)
(Frequency setting mode selection 1) = 2 (RR/S4)
(Input terminal selection 2 (R)) = 48 (Remote/Local control)
F-CC terminal short to RUN
F-CC terminal short to STOP
Output frequency is set up by the RR/S4 signal input.
- 18 -
Detailed contents
Normal completion of instruction code execution
Execution error.
(Write protected during operation)
Unregistered code number was set.
Set data is outside the setting data range.
E6581286②
VF-AS1
PP
RR/S4
CCA
SW1
F
SOURCE
SINK
R
CC

Advertisement

Table of Contents
loading