SEBU8455
Table 12
Equation For Adding The SCA To The Heavy-Duty
Coolant For Maintenance
V × 0.014 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 13 is an example for using the equation that
is in Table 12.
Table 13
Example Of The Equation For Adding The SCA To
The Heavy-Duty Coolant For Maintenance
Total Volume
Multiplication
of the Cooling
Factor
System (V)
15 L (4 US gal)
× 0.014
Cleaning the System of Heavy-Duty
Antifreeze
Perkins cooling system cleaners are designed
to clean the cooling system of harmful scale
and corrosion. Perkins cooling system cleaners
dissolve mineral scale, corrosion products, light oil
contamination, and sludge.
Clean the cooling system after used coolant is
drained or before the cooling system is filled with
new coolant.
Clean the cooling system whenever the coolant is
contaminated or whenever the coolant is foaming.
Amount of
SCA that is
Required (X)
0.2 L (7 oz)
59
Maintenance Section
Refill Capacities