Disassembly Of The Parts (Indoor Unit); Indoor Unit - LG AMNH096BTG0 Manuals

Multi type air conditioner
Hide thumbs Also See for AMNH096BTG0:
Table of Contents

Advertisement

Disassembly of the parts (Indoor unit)

Indoor unit

1. Split Type Indoor unit
CAUTION: Disconnect the unit
from power supply before making
any checks.
Be sure the power switch is set to
"OFF".
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift
it straight upward.
1) To remove the sensor, housing connect,
earth conductor & step motor conductor with
sensor holder, Motor, Evaporator & P.C.B.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Earth
Conductor
- 127 -
Disassembly of the parts
Screw
Motor
Conductor
Power
Conductor
Sensor
Conductor
Step Motor
Conductor
LGE Internal Use Only