Fusing Idling Temperature - Ricoh B079 Service Manual

Hide thumbs Also See for B079:
Table of Contents

Advertisement

IMAGE FUSING AND PAPER EXIT

Fusing Idling Temperature

If copies are not sufficiently fused soon after the main power switch is turned on,
fusing idling should be enabled with SP1103 1.
When fusing idling is enabled, it is done when the temperature reaches the print
ready ("re-load") temperature. The re-load temperature can be adjusted with
SP1105 5,6.
In the opposite case, even if fusing idling is disabled, it is done when the
temperature at power-up ≤ 15 °C
The fusing idling time is as follows.
Temperature at
power-on
15 °C or less
Higher than 15°C
B079/B082
CÓPIA NÃO CONTROLADA
Fusing Idling Mode
0: Disabled
1: Enabled
30 s
Not done
6-98
CÓPIA NÃO CONTROLADA
SP1103 1
30 s
SP1103 2
30 s
SM

Hide quick links: