Rapid Advance Mode - Dexter Laundry T-900 Operator's Manual

Industrial washer model t-900/950 on-premise n-series control
Table of Contents

Advertisement

3.4

RAPID ADVANCE MODE

Rapid Advance mode is a key-controlled override to interrupt the current
cycle, drain the water, and advance to the next mode of the wash cycle,
including Pre Wash, Wash, Rinse 1, Rinse 2, Rinse 3, Rinse 4, Rinse 5, and
Final Rinse. The indicator lights will show to which segment the cycle has
been advanced.
To enter the Rapid Advance mode, insert the key into the Rapid
Advance/Run/Program lock and turn the key counter-clockwise (CCW).
The Rapid Advance mode must be entered during a cycle. If the cycle has
not yet started, press the "DOWN" button or the "UP" button to choose a
cycle and then the "START" button to begin the cycle.
To advance to the next step in the cycle, press both the "UP" and "START"
buttons at the same time. The display will show "Ad" (advance).
If advancing during a bath, all water valves will turn off and the drain will
open until the "open drain" step is completed. The cycle will then
continue to the next bath or to the spin of the current bath if the
programming includes spin time.
If advancing during a chemical injection of a bath or after a chemical
injection of the bath but before the low water level is reached, the injector
will turn off and the hot and the cold water valves to the tub will turn on
until the low water level is reached or for 30 seconds, whichever comes
first. Then the drain will open and proceed to the next step after the
"open drain" step is completed.
If advancing before a chemical injection of the bath, the drain will open
immediately and the cycle will proceed to the next step when the "open
drain" step is completed.
If advancing during a spin, the tumbler will begin to decelerate
immediately. However, the cycle may proceed to the next bath before the
tumbler comes to a complete stop. The cycle cannot be advanced further
while the tumbler is decelerating.
If a temperature PCB is installed in the I/O PCB and the temperature
programmed from 20°C to 90°C, advancing will turn off the heater relay
or steam valve immediately, if either is on, and open the drain after a
three second delay. If the display shows a water temperature from 65°C
to 90°C (may be displayed by pressing the "DOWN" and "START" buttons
together), the drain will close again when the washer indicates empty and
the hot and the cold water valves to the tub will turn on until the low
water level is reached. The cycle will then continue to the next bath, or if
programmed, to the spin of the current bath.
To exit the Rapid Advance mode during the cycle, turn the key to
"RUN". The cycle will continue normally.
8514-244-001 REV PR page 30