Parallel-Port Interface; Connector - Kontron MOPSPM104 User Manual

Table of Contents

Advertisement

Chapter 11

11. Parallel-Port Interface

The MOPSPM104 incorporates a parallel port that can be set to uni-/bidirectional and supports EPP/ECP
operating modes.

11.1 Connector

The parallel port is available through the X10 connector (32 pins). To have the signals available on a
standard, parallel interface connector DSUB-25, an adapter cable is required, which is offered by Kontron
(KAB-DSUB25-2, Part Number 61033). The following table shows the pinout as well as necessary connec-
tions for a DSUB-25 adapter.
Header
1
32
Note:
To protect the external power lines of peripheral devices, make sure that
1
- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.
To find the location of the parallel port on the MOPSPM104 board, please see the Appendix "Connector Lay-
out".
Kontron User's Guide MOPSPM104
Pin
Signal Name
13
/STB
15
PD0
18
PD1
20
PD2
21
PD3
23
PD4
24
PD5
25
PD6
26
PD7
28
/ACK
29
/BUSY
30
PE
31
/SLCT
12
/AFD
14
/ERR
16
/INIT
19
/SLIN
1
(1)
VCC
2,11
GND
17,22
GND
27,32
GND
24
Function
In / Out
Strobe
Out
Data 0
I/O
Data 1
I/O
Data 2
I/O
Data 3
I/O
Data 4
I/O
Data 5
I/O
Data 6
I/O
Data 7
I/O
Acknowledge
In
Busy
In
Paper out
In
Select out
In
Autofeed
Out
Error
In
Init
Out
Select in
Out
+ 5V
--
Signal Ground
--
Signal Ground
--
Signal Ground
--