5-6. Activating The Dry Charge Battery (If Applicable)

1
Tools Needed:

5-7. Connecting The Battery

Tools Needed:
1/2 in
OM-236 948 Page 22
3
2
4
+
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
5
5 Amperes For 30 Minutes
Charge Time
6
30 Amperes For 12 Minutes
5
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
5 A
6
30 A
!
Connect negative (−) battery
cable last.
.
Close door after connecting
battery.