Activating The Dry Charge Battery (If Applicable); Connecting The Battery - Miller Big Blue 350 PipePro Owner's Manual

Hide thumbs Also See for Big Blue 350 PipePro:
Table of Contents

Advertisement

5-6. Activating The Dry Charge Battery (If Applicable)

1
4
+

5-7. Connecting The Battery

OM-244 620 Page 24
3
2
5
OR
5 A
+
Tools Needed:
6
30 A
Tools Needed:
.
Shown with rocker
panel removed.
1/2 in.
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
5
5 Amperes For 30 Minutes
Charge Time
6
30 Amperes For 12 Minutes
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
dry_batt2 2010−04 − S-0886
!
Connect negative (−) battery
cable last.
.
Close door after connecting
battery.
Conn_Batt2 2010−04 / S-0756-C / 161-002

Advertisement

Table of Contents
loading

Table of Contents